Effect of decentration of wavefront-corrected intraocular lenses on the higher-order aberrations of the eye.
نویسندگان
چکیده
OBJECTIVE To evaluate the theoretical effect of decentration of aspherical intraocular lenses (IOLs) and wavefront-corrected IOLs up to the sixth order on higher-order aberrations (HOAs) (third through sixth order) of the eye. METHODS An aspherical IOL with HOAs of fourth-order spherical aberrations only (-0.287 microm with a 6-mm pupil) and a wavefront-corrected IOL with HOAs of equal magnitude and opposite from the corneal HOAs were created and laterally shifted up to 1 mm to simulate decentered IOLs. The residual HOAs for pupils of 3 to 6 mm were calculated by combining the HOAs from the cornea and the decentered IOL. Based on the residual HOAs, optical quality was rated by 3 criteria: the Marechal criterion, a diffraction-limited optical system with an aberration less than lambda/14; P(10), the lower 10th percentile of the corneal HOAs in this study group; and decreased HOA, residual ocular HOAs less than the corresponding corneal HOAs. RESULTS Simulated implantation of the aspherical IOLs and wavefront-corrected IOLs was performed in 154 eyes of 94 patients aged 40 to 80 years. For a centered aspherical IOL and a 6-mm pupil, no eyes met the Marechal criterion, and the P(10) and decreased-HOA criteria were met by 46% and 93% of eyes, respectively. For a 6-mm pupil, the required centration was 0.47 mm to meet the decreased-HOA criterion in 50% of eyes. With a wavefront-corrected IOL and a 6-mm pupil, the centrations required to meet the criteria for 90% of eyes were 0.04 mm for the Marechal criterion, 0.36 mm for P(10), and 0.48 mm for the decreased-HOA criterion. CONCLUSION Excellent centration is required to maximize the visual outcome of wavefront-corrected IOLs. CLINICAL RELEVANCE With current surgical techniques, implantation of aspherical IOLs and wavefront-corrected IOLs will reduce total ocular HOAs below corneal HOAs in approximately 45% and 86% of eyes (6-mm pupil), respectively.
منابع مشابه
Theoretical comparison of aberration-correcting customized and aspheric intraocular lenses.
PURPOSE To assess the performance and optical limitations of standard, aspheric, and wavefront-customized intraocular lenses (IOLs) using clinically verified pseudophakic eye models. METHODS White light pseudophakic eye models were constructed from physical measurements performed on 46 individual cataract patients and subsequently verified using the clinically measured contrast sensitivity fu...
متن کاملکاربرد لنزهای داخل چشمی در جراحی کاتاراکت و عوامل تأثیرگذار بر دید بیمار
Introduction: With the growing and rapid development of refractive surgery, researches focus increasingly on improvement of visual quality after cataract surgery. Intraocular lenses (IOLs) were a successful effort in the field of cataract surgery. Despite significant advances in cataract surgery, several complications related to surgical technique and IOL design after surgery can cause vision c...
متن کاملGeneration of Higher Order Aberrations with Soft Contact Lens by Excimer Laser Ablation
Although the human eye has a relatively simple optical system, it is not perfect. It has been well known that the human eye suffers from the wavefront aberration that includes both lower (defocus and astigmatism) and higher order aberrations. The lower order aberration has been effectively corrected with conventional ophthalmic lenses such as spectacles and contact lenses. However, it is more c...
متن کاملCustomized computer models of eyes with intraocular lenses.
We compared experimental wave aberrations in pseudophakic eyes with aspheric intraocular lenses (IOLs) to simulate aberrations from numerical ray tracing on customized computer eye models using corneal topography, angle lambda, ocular biometry, IOL geometry, and IOL tilt and decentration measured on the same eyes. We found high correlations between real and simulated aberrations even for the ey...
متن کاملTilt, Decentration, and Internal Higher-Order Aberrations of Sutured Posterior-Chamber Intraocular Lenses in Patients with Open Globe Injuries
Purpose To evaluate the tilt, decentration, and internal higher-order aberrations (HOAs) of sutured posterior-chamber intraocular lenses (IOLs) in patients with open globe injuries. Methods 46 consecutive patients (47 eyes) who underwent transsclerally sutured IOL implantation were enrolled in this prospective cohort study. Nineteen eyes had a history of open globe injury. The tilt and decent...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Archives of ophthalmology
دوره 123 9 شماره
صفحات -
تاریخ انتشار 2005