Degradation of trans-polyisoprene after root filling with thermoplasticized techniques.
نویسندگان
چکیده
AIM To evaluate ex vivo degradation of gutta-percha following six thermoplastic obturation techniques. METHODOLOGY Ninety human-extracted mandibular premolars were selected and divided randomly into nine groups for filling. Group 1: thermomechanical compaction for 3 s with Konne gutta-percha points (Konne Ind. e Com. de Mat. Odontol., Belo Horizonte, MG, Brazil); Group 2: thermomechanical compaction for 3 s with Dentsply TP gutta-percha points (Dentsply Indústria e Comércio Ltda, Petrópolis, R.J. Brazil); Group 3: thermomechanical compaction for 10 s with Konne; Group 4: thermomechanical compaction for 10 s with Dentsply TP; Group 5: warm vertical condensation using System B (EIE/Analytic, Richmond, WA, USA) with Konne; Group 6: warm vertical condensation using System B with Dentsply TP; Group 7: vertical condensation with Konne; Group 8: vertical condensation with Dentsply TP; Group 9: Microseal cone (Analytic Endodontics, Glendora, CA, USA). A further four groups were assessed without using teeth, Group 10: Microseal microflow (Analytic Endodontics); Group 11: Obtura (Obtura Corporation, Penton, MO, USA); Group 12: Obtura flow (Obtura Corporation); Group 13: Thermafil (Dentsply Maillefer, Tulsa, OK, USA). The filling material was removed from the root canal and trans-1,4-polyisoprene isolated by solubilization of the root filling remnants in chloroform followed by filtration and centrifugation. By gel permeation chromatography and infrared spectroscopy, the occurrence and degree of degradation were assessed. The results were analysed statistically using the Kruskal-Wallis test. With differential scanning calorimetry, the thermal behaviour of the gutta-percha was determined. RESULTS A significant decrease in polymer molar mass and the production of carboxyl and hydroxyl groups in the polymer were observed with thermomechanical compaction used for 10 s and vertical condensation filling techniques (P = 0.0001 and P = 0.0005, respectively). Other techniques caused no polymer degradation. CONCLUSION Polyisoprene degrades with high temperature. Thermomechanical compaction for 10 s and vertical condensation were associated with the greatest degradative process.
منابع مشابه
Clinical relevance of trans 1,4-polyisoprene aging degradation on the longevity of root canal treatment.
This in vivo study investigated the time of degradation of root filling material (trans 1,4-polyisoprene) retrieved from endodontically treated teeth and correlated the occurrence of degradation with the longevity of endodontics. Thirty-six root-filled teeth with different filling times (2 to 30 years) and with and without periapical lesions were selected. All teeth presented clinical indicatio...
متن کاملFP core carrier technique: thermoplasticized gutta-percha root canal obturation technique using polypropylene core.
Core carrier techniques are unique among the various root canal filling techniques for delivering and compacting gutta-percha in the prepared root canal system. Thermafil (TF), considered the major core carrier device, is provided as an obturator consisting of a master core coated with thermoplasticized gutta-percha. We have devised a thermoplasticized gutta-percha filling technique using a pol...
متن کاملA comparison of laterally condensed gutta-percha, thermoplasticized gutta-percha, and mineral trioxide aggregate as root canal filling materials.
The purpose of this study was to evaluate the potential of using mineral trioxide aggregate as a root canal filling material by comparing its apical sealing ability with that of laterally condensed gutta-percha with sealer and high-temperature thermoplasticized gutta-percha with sealer in extracted bovine teeth. Sixty bovine incisors with single canals were prepared in a standard manner using L...
متن کاملInfluence of irrigation and obturation techniques on artificial lateral root canal filling capacity.
The aim of this study was to evaluate the influence of two different irrigation protocols on artificial lateral root canal filling capacity using different obturation techniques. Sixty single-root human teeth were used. Two artificial lateral canals were created in the apical third. Root canals were instrumented up to a 45 K-file to the working length. Before each file, root canals were irrigat...
متن کامل3D Analysis of D-RaCe and Self-Adjusting File in Removing Filling Materials from Curved Root Canals Instrumented and Filled with Different Techniques
The aim of this study was to compare the efficacy of D-RaCe files and a self-adjusting file (SAF) system in removing filling material from curved root canals instrumented and filled with different techniques by using microcomputed tomography (micro-CT). The mesial roots of 20 extracted mandibular first molars were used. Root canals (mesiobuccal and mesiolingual) were instrumented with SAF or Re...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- International endodontic journal
دوره 41 4 شماره
صفحات -
تاریخ انتشار 2008