The dependence of myocardial ultrasonic integrated backscatter on contractile performance.
نویسندگان
چکیده
We have recently shown that the cardiac cycle-dependent variation in myocardial ultrasonic integrated backscatter is blunted with regional ischemia in dogs. To determine if global and intramural regional myocardial contractile performance can be quantified by integrated backscatter, we analyzed ultrasonic responses after induction of increased and decreased contractility in five dogs. A recently developed analog data-acquisition system for measuring integrated backscatter in real time was used to sample radiofrequency signals gated from subepicardial or subendocardial regions. Base-line recordings of integrated backscatter, left ventricular pressure, left ventricular dP/dt, and wall thickness were made at 12 left ventricular sites for both intramural regions. Contractility was modified subsequently by either paired pacing or propranolol to produce significantly elevated or depressed values for maximum left ventricular dP/dt compared with baseline (1083 +/- 289 to 3001 +/- 570 mm Hg/sec; p less than .01 for all). The amplitude of the cyclic variation of integrated backscatter was 50% greater (arithmetically) in subendocardial than in subepicardial regions for all treatments (7.6 +/- 0.3 vs 6.0 +/- 0.5 dB, p less than .001). The maximum rate of change in integrated backscatter waveforms during isovolumetric contraction was faster with paired pacing and slower with propranolol than at baseline for all regions (56 +/- 6 to 74 +/- 6 to 82 +/- 5 dB/sec, p less than .005). The maximum rate of change in integrated backscatter also was greater in subendocardial than subepicardial regions (p less than .001). Thus, both regional and global differences in myocardial contractile performance are manifest quantitatively in integrated backscatter waveforms. We propose that the physiologic determinants of these differences may depend on regional and global variations in myofibril elastic characteristics.
منابع مشابه
LABORATORY INVESTIGATION TISSUE CHARACTERIZATION The dependence of myocardial ultrasonic integrated backscatter on contractile performance*
We have recently shown that the cardiac cycle-dependent variation in myocardial ultrasonic integrated backscatter is blunted with regional ischemia in dogs. To determine if global and intramural regional myocardial contractile performance can be quantified by integrated backscatter, we analyzed ultrasonic responses after induction of increased and decreased contractility in five dogs. A recentl...
متن کاملA relationship between ultrasonic integrated backscatter and myocardial contractile function.
We have shown previously that the physiologic, mechanical cardiac cycle is associated with a parallel, cardiac cycle-dependent variation of integrated backscatter (IB). However, the mechanisms responsible are not known. The mathematical and physiological considerations explored in the present study suggest that the relationship between backscatter and myocardial contractile function reflects cy...
متن کاملEstimation of myocardial infarct size with ultrasonic tissue characterization.
BACKGROUND Ultrasonic tissue characterization (UTC) can distinguish normal from infarcted myocardium. Infarcted myocardium shows an increase in integrated backscatter and loss of cardiac cycle-dependent variation in backscatter. The cyclic variation of backscatter is closely related to regional myocardial contractile function; the latter is a marker of myocardial ischemia. The present study was...
متن کاملUltrasonic tissue characterization with integrated backscatter. Acute myocardial ischemia, reperfusion, and stunned myocardium in patients.
We have previously shown in studies of experimental animals that myocardium exhibits a cardiac cycle-dependent variation of integrated backscatter that reflects regional myocardial contractile performance and that is blunted promptly after arterial occlusion and recovers after reperfusion. To define the clinical utility of ultrasonic tissue characterization with integrated backscatter for detec...
متن کاملRegional variations of ultrasonic integrated backscatter in normal and myopathic left ventricles. A new multi-view approach.
The purpose of the present study was to determine whether the cyclic variation of integrated backscatter is measurable and quantifiable in all left ventricular walls and whether the information obtained using both parasternal and apical transducer positions can be used to identify changes in myocardial structure and contractility. The cyclic variation of integrated backscatter was measured from...