A high-spatial-resolution fiber-optic-coupled CMOS imager with novel scintillator for high-energy x-ray applications

نویسندگان

  • Robin M. Baur
  • Mark W. Tate
  • Darren S. Dale
  • Sol M. Gruner
چکیده

A fast, high-spatial-resolution detector for high-energy microscopy work is presented. The detector uses a 2160 x 2560 CMOS chip for fast framing (up to 100 Hz in full-frame mode), coupled by a fiber optic taper to a scintillating Terbium-doped fiber optic plate for excellent stopping power even at high energies. The field of view is 7mm × 8.6mm with a resolution of 9 microns. The sensitivity is 1 e-/x-ray at 35 keV, with a read noise of 2.5 e-/pixel. Standard characterization metrics including dark current, sensitivity, modulation transfer function, and detective quantum efficiency are presented, along with preliminary experimental results.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Developing a high-resolution x-ray imager using electron-multiplying (EM) CCDs

Applications at synchrotron facilities such as macromolecular crystallography and high energy X-ray diffraction require high resolution imaging detectors with high dynamic range and large surface area. Current systems can be split into two main categories: hybrid pixel detectors and scintillator-coupled Charge-Coupled Devices (CCDs). Whilst both have limitations, CCD-based systems (coupled to f...

متن کامل

Photon-counting imaging camera for high-resolution X-ray and -ray applications

Standard X-ray imaging techniques using CCDs require the integration of thousands of X-ray photons into a single image frame. Through the addition of a scintillating layer to the CCD it is possible to greatly increase the X-ray detection efficiency at high energies. Using standard imaging techniques with the inclusion of the scintillating layer does, however, leave serious limitations on the sp...

متن کامل

Co Irradiation Chamber

Due to its excellent remote measurability and high spatial resolution, the fiber optic-based radiation dosimeter has been extensively explored for its usability in medical applications by several researchers [1-2]. In the previous work [3,4], we reported the result of our investigation on feasibility of a photon dosimeter constructed with a BGO(Bi4Ge3O12) or GSO(Gd2SiO5) scintillator piece coup...

متن کامل

Implementation of a Data Acquisition System for 2×2 Fiber Optic Taper Array Coupled Digital X-ray Detector

Fiber optic taper (FOP) array coupled digital x-ray detector can be an ideal choice for large area high resolution x-ray imaging, but its data acquisition system is a challenge, for the reasons such as restrictions of hardware design due to the shape of the FOP array, long distance control requirement in x-ray environment, and arrangement of data transmission sequence among multiple CCD/CMOS im...

متن کامل

Recent developments in X-ray imaging with micrometer spatial resolution.

X-ray detectors for imaging with a spatial resolution in the micrometer and submicrometer range have been developed at synchrotron radiation sources since 1996. The detectors consist of a scintillator, a light microscopy optic and a charge-coupled device (CCD). The scintillator converts part of the X-ray stopped by a material into a visible-light image which is projected onto the CCD by the lig...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013