Radiation dose reduction with hybrid iterative reconstruction for pediatric CT.

نویسندگان

  • Sarabjeet Singh
  • Mannudeep K Kalra
  • Anuradha S Shenoy-Bhangle
  • Aashna Saini
  • Debra A Gervais
  • Sjirk J Westra
  • James H Thrall
چکیده

PURPOSE To assess image quality and radiation dose reduction with hybrid iterative reconstruction of pediatric chest and abdominal computed tomographic (CT) data compared with conventional filtered back projection (FBP). MATERIALS AND METHODS A total of 234 patients (median age, 12 years; age range, 6 weeks to 18 years) underwent chest and abdominal CT in this institutional review board-approved HIPAA-compliant retrospective study. CT was performed with a hybrid adaptive statistical iterative reconstruction (ASIR)-enabled 64-detector row CT scanner. Scanning protocols were adjusted for clinical indication and patient weight to enable acquisition of reduced-dose CT images in all patients, and tube current was further lowered for ASIR protocols. Weight, age, and sex were recorded, and objective noise was measured in the descending thoracic aorta for chest CT and in the liver for abdominal CT. Of the 234 consecutive patients who underwent ASIR-enabled CT (115 chest and 119 abdominal examinations), 70 patients had undergone prior FBP CT. ASIR and FBP CT studies (29 chest and 41 abdominal studies) in these 70 patients were reviewed for image quality, artifacts, and diagnostic confidence by two pediatric radiologists working independently. Data were analyzed with multiple paired t tests. RESULTS Compared with FBP, ASIR enabled dose reduction of 46.4% (3.7 vs 6.9 mGy) for chest CT and 38.2% (5.0 vs 8.1 mGy) for abdominal CT (P < .0001). Both radiologists deemed image quality of and diagnostic confidence with ASIR and FBP CT images as acceptable, without any artifacts. Despite the lower radiation dose used, ASIR images (chest, 10.7 ± 2.5 [mean ± standard deviation]; abdomen, 11.8 ± 3.4) had substantially less objective noise than did FBP images (chest, 13.3 ± 3.8; abdomen, 13.8 ± 5.2) (P = .001, P =.006, respectively). CONCLUSION Use of a hybrid iterative reconstruction technique, such as ASIR, enables substantial radiation dose reduction for pediatric CT when compared with FBP and maintains image quality and diagnostic confidence.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Application of Different methods for Reducing Radiation Dose to Breast during MDCT

The increased use of computed tomography (CT) and its high radiation dose have led to great concerns about its potential for radiation induced cancer risks. Breast is a radiosensitive tissue based on tissue weighting factors assigned by the International Commission on Radiological Protection (ICRP). Moreover, the dose is maximal on the surface of the patient. Therefore, strategies should be tak...

متن کامل

Comparing IDREAM as an Iterative Reconstruction Algorithm against In Filtered Back Projection in Computed Tomography

Introduction: Recent studies of Computed Tomography (CT) conducted on patient dose reduction have recommended using an iterative reconstruction algorithm and mA (mili-Ampere) dose modulation. The current study aimed to evaluate Iterative Dose Reduction Algorithm (IDREAM) as an iterative reconstruction algorithm. Material and Methods: Two CT p...

متن کامل

Low-dose computed tomography with 4th-generation iterative reconstruction algorithm in assessment of oncologic patients

AIM To compare radiation dose and image quality of low-dose computed tomography (CT) protocol combined with hybrid-iterative reconstruction algorithm with standard-dose CT examinations for follow-up of oncologic patients. METHODS Fifty-one patients with known malignant diseases which underwent, during clinical follow-up, both standard-dose and low-dose whole-body CT scans were enrolled. Low-d...

متن کامل

Radiation dose reduction in medical x-ray CT via Fourier-based iterative reconstruction.

PURPOSE A Fourier-based iterative reconstruction technique, termed Equally Sloped Tomography (EST), is developed in conjunction with advanced mathematical regularization to investigate radiation dose reduction in x-ray CT. The method is experimentally implemented on fan-beam CT and evaluated as a function of imaging dose on a series of image quality phantoms and anonymous pediatric patient data...

متن کامل

Radiation dose reduction in pediatric great vessel stent computed tomography using iterative reconstruction: A phantom study

BACKGROUND To study dose reduction using iterative reconstruction (IR) for pediatric great vessel stent computed tomography (CT). METHODS Five different great vessel stents were separately placed in a gel-containing plastic holder within an anthropomorphic chest phantom. The stent lumen was filled with diluted contrast gel. CT acquisitions were performed at routine dose, 52% and 81% reduced d...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Radiology

دوره 263 2  شماره 

صفحات  -

تاریخ انتشار 2012