Rapid and accurate CO2 isotopic measurement in whole blood: comparison with expired gas

نویسندگان

  • MARTIAL DANGIN
  • BERNARD BEAUFRÈRE
چکیده

Dangin, Martial, Jean Claude Desport, Pierre Gachon, and Bernard Beaufrère. Rapid and accurate CO2 isotopic measurement in whole blood: comparison with expired gas. Am. J. Physiol. 276 (Endocrinol. Metab. 39): E212–E216, 1999.—Determination of CO2 enrichment on the CO2 released from blood by acid has been used in situations in which breath sampling is difficult. This method can be improved by measuring this enrichment on the CO2 spontaneously released from blood. Therefore, simultaneous comparisons of CO2 content between breath and arterialized blood added with or without acid were performed in 51 samples from human studies, using the statistical method of Bland and Altman (J. M. Bland and D. G. Altman. Lancet 1: 307–310, 1986). Strong relationships exist between the methods (r . 0.99) expressed in atom percent excess (APE). Compared with breath, the acid method overestimates the CO2 enrichment (0.318 6 0.632 APE 3 1,000, P , 0.001). The acid-free method shows similar enrichments to breath (0.003 6 0.522 APE 3 1,000, P 5 0.97) with good precision and degree of agreement (95% confidence interval 0.15 APE 3 1,000). The analysis can be performed up to 5 days after sampling with a good reproducibility. In conclusion, measuring CO2 enrichments on the CO2 spontaneously released from blood is feasible, gives identical results to the breath method, and lessens operator manipulations. It allows study of situations in which the breath sampling method is not feasible.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Rapid and accurate13CO2isotopic measurement in whole blood: comparison with expired gas.

Determination of13CO2enrichment on the CO2 released from blood by acid has been used in situations in which breath sampling is difficult. This method can be improved by measuring this enrichment on the CO2 spontaneously released from blood. Therefore, simultaneous comparisons of13CO2content between breath and arterialized blood added with or without acid were performed in 51 samples from human ...

متن کامل

CO2 transport in normovolemic anemia: complete compensation and stability of blood CO2 tensions.

Isovolemic hemodilution does not appear to impair CO2 elimination nor cause CO2 retention despite the important role of red blood cells in blood CO2 transport. We studied this phenomenon and its physiological basis in eight New Zealand White rabbits that were anesthetized, paralyzed, and mechanically ventilated at a fixed minute ventilation. Isovolemic anemia was induced by simultaneous blood w...

متن کامل

Development of a spectroscopic technique for continuous online monitoring of oxygen and site-specific nitrogen isotopic composition of atmospheric nitrous oxide.

Nitrous oxide is an important greenhouse gas and ozone-depleting-substance. Its sources are diffuse and poorly characterized, complicating efforts to understand anthropogenic impacts and develop mitigation policies. Online, spectroscopic analysis of N2O isotopic composition can provide continuous measurements at high time resolution, giving new insight into N2O sources, sinks, and chemistry. We...

متن کامل

Measurement of short-term changes in the fat content of the body: a comparison of three methods in patients receiving intravenous nutrition.

Three methods of measuring changes in body fat were compared in seventeen patients undergoing a 2-week course of intravenous nutrition. Patients received all nutrition intravenously at a steady rate of infusion, calculated to supply energy at a rate equal to 1.5 times the resting metabolic expenditure measured before feeding. Fat change was estimated from measurements of skinfold thickness, by ...

متن کامل

CO2 Measurement of Synthetic Biogas by Passing It through Dilute NaOH Solution

The feasibility of measuring CO2 content in biogas was evaluated in this research. Firstly, Curtipot pH simulator was used to visualize the titration behaviors of various percentages of dissolved CO2 in a wide range of concentrations of NaOH solution. As a general output of those simulations, it was shown that when the titration curves of different CO2 conte...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1998