Twenty-year durability of the aortic Hancock II bioprosthesis in young patients: is it durable enough?.
نویسندگان
چکیده
OBJECTIVES There is a current trend towards the use of bioprosthetic aortic valves in the aortic position in young patients, but there is limited information on durability beyond the first decade. The Hancock II bioprosthesis has been reported to have excellent durability in patients ≥ 60 years of age. This study examines the long-term durability of the Hancock II bioprosthesis in the aortic position in patients <60 years of age. METHODS From 1982 to 2008, 304 patients aged 59 years or less underwent aortic valve replacement (AVR) with a Hancock II bioprosthesis at two centres. The mean age was 49.2 ± 9.0 years, and 79% of the patients were male. Valve function was serially assessed by echocardiography. The median follow-up was 14.6 years (maximum 27.5 years). Survival and freedom from adverse events were calculated by using a Kaplan-Meier method. Independent predictors of those events were assessed by using Cox proportional hazards analyses. RESULTS Survival and freedom from repeat AVR (re-AVR) at 20 years were 57.0 ± 6.1 and 25.4 ± 4.7%, respectively. During the follow-up, 100 patients (33%) underwent re-AVR: 78 for structural valve deterioration (SVD), 11 for endocarditis, 4 for non-structural valve dysfunction and 7 for other reasons. The overall 10-, 15- and 20-year freedom from re-AVR due to SVD were 91.4 ± 2.1, 64.7 ± 4.3 and 29.1 ± 5.3%, respectively. By age group, the 20-year freedom from re-AVR due to SVD amounted to 14.1 ± 8.7% in patients younger than 40 years of age, 21.5 ± 8.5% in patients aged 40-49 and 41.4 ± 8.2% in patients between 50 and 59 (P = 0.04). The independent predictors of re-AVR due to SVD were age [odds ratio (OR): 0.72 per 10 years; 95% confidence interval (CI): 0.58, 0.90; P < 0.01] and prosthesis-patient mismatch (PPM) (effective orifice area index <0.80 cm(2)/m(2)) (OR: 1.63; 95% CI: 1.01, 2.63; P = 0.045). CONCLUSIONS The Hancock II bioprosthesis for AVR in patients <60 years of age is associated with excellent durability during the first decade. However, SVD increases dramatically during the second decade and by 20 years, especially in patients aged <50 and/or with PPM. These findings may assist prosthesis selection for patients and their surgeons.
منابع مشابه
Exercise Hemodynamics and Quality of Life after Aortic Valve Replacement for Aortic Stenosis in the Elderly Using the Hancock II Bioprosthesis
Background and Aim. While aortic valve replacement for aortic stenosis can be performed safely in elderly patients, there is a need for hemodynamic and quality of life evaluation to determine the value of aortic valve replacement in older patients who may have age-related activity limitation. Materials and Methods. We conducted a prospective evaluation of patients who underwent aortic valve rep...
متن کاملeComment. A novel lower age threshold for use of biological valves.
valve-in-valve implantation for the treatment of stentless aortic valve dysfunction. J Thorac Cardiovasc Surg 2010;140:246–8. [11] Ferrari E, Marcucci C, Sulzer C, von Segesser LK. Which available transapical transcatheter valve fits into degenerated aortic bioprostheses? Interact CardioVasc Thorac Surg 2010;11:83–5. [12] Ye J, Webb JG, Cheung A, Soon JL, Wood D, Thompson CR et al. Transapical ...
متن کاملAortic valve replacement with stentless and stented porcine valves: a case-match study.
OBJECTIVES To assess the potential benefits of the hemodynamic superiority of stentless valves, we conducted a case-match study among patients who underwent aortic valve replacement with two types of porcine bioprostheses: the Toronto SPV and the stented Hancock II bioprosthesis. METHODS Preoperative clinical variables predictive of death after aortic valve replacement were determined by a st...
متن کاملDurability of pericardial versus porcine aortic valves.
OBJECTIVES This study compares the long-term performance of the Carpentier-Edwards (CE) porcine bioprosthesis and the CE pericardial bioprosthesis for aortic valve replacement (AVR). BACKGROUND With new bioprostheses on the horizon, there is renewed interest in how the long-term durability of current pericardial bioprostheses compares with the traditional porcine bioprosthesis. METHODS We r...
متن کاملThe fate of Hancock II porcine valve recipients 25 years after implant.
OBJECTIVE The Hancock II (HII) is a second-generation porcine bioprosthesis introduced into clinical use in 1982. This study aimed to evaluate very long-term outcomes for the HII valve in a large patient population. METHODS Between May 1983 and November 1993, 517 consecutive patients (pts) (309 male, mean age: 64+/-9 years) underwent valve replacement (VR) surgery with HII, with 302 (58.4%) i...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery
دوره 46 5 شماره
صفحات -
تاریخ انتشار 2014