Retention time precision of Agilent 1290 Infinity Quaternary Pump Analysis of clopidol using dynamically and premixed gradients

ثبت نشده
چکیده

The most important performance parameter for an ultrahigh performance liquid chromatography (UHPLC) pump is precision of retention times. Highest precision is required to identify compounds by retention times and subsequently accurately quantify the analyzed sample compounds. Gradient analysis can be done using either premixed mobile phases applying gradients from 0 to 100% B, as described in some USP methods, or using dynamically-mixed mobile phases applying gradients, for example, from 10 to 80% B. This Technical Overview shows that premixing mobile phases for gradient applications provides retention time precisions below specifications, even under demanding chromatographic conditions. It also shows that dynamically-mixed gradients with the Agilent 1290 Infinity Quaternary Pump improve retention time precision significantly. The results of the 1290 Infinity Quaternary Pump are compared to results obtained using a quaternary pump from a non-Agilent manufacturer. Author Angelika Gratzfeld-Huesgen Agilent Technologies, Inc. Waldbronn, Germany min 6.2 6.4 6.6 6.8 7 7.2 7.4 7.6 250 300 mAU 0 50 100 150 200 Dynamically mixed gradient RSD RT = 0.015%

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimizing protein separations with cation exchange chromatography using Agilent Buffer Advisor Protein separation with the Agilent 1260 Infinity Bio‐inert Quaternary LC System

This Technical Overview shows that the Agilent Buffer Advisor software in com‐ bination with the Agilent 1260 Infinity Bio‐inert Quaternary LC System is an ideal solution for automated protein separation by ionic strength gradients. Usually, pH scouting using premixed two‐component gradients is time‐consuming and work‐ intensive. Dynamically mixed four‐component gradients calculated by the Buff...

متن کامل

Optimizing protein separations with cation exchange chromatography using Agilent Buffer Advisor

This Technical Overview shows that the Agilent Buffer Advisor software in combination with the Agilent 1260 Infi nity Bio-inert Quaternary LC System is an ideal solution for automated protein separation by ionic strength gradients. Usually, pH scouting using premixed two-component gradients is time-consuming and workintensive. Dynamically mixed four-component gradients calculated by the Buffer ...

متن کامل

Performance of the Agilent 1290 Infinity Quaternary Pump using Trifluoroacetic Acid (TFA) as the mobile phase modifier

In liquid chromatography, baseline noise should be as low as possible to provide an optimum signal-to-noise ratio and to enable reliable integration of peaks at trace level. Baseline noise has different sources. One source is the detector, and another is the mixing performance of the pump, which is especially important if, for example, trifluoroacetic acid (TFA) is used as modifier in the mobil...

متن کامل

Transferring and optimizing the determination of explosives to fast and high resolution chromatography

This Application Note describes the method for detection of nanogram levels of explosive constituents in seawater samples, after explosion of ordnance devices. Sample preparation is done by enrichment on highly cross-linked polystyrenedivinylbenzene (PS-DVB) cartridges such as the Agilent SampliQ PS-DVB. The improved chromatographic method was developed using the Method Development System from ...

متن کامل

Fast analysis of ink dyes using the Agilent 1290 Infinity LC System coupled to Agilent 6140 single quadrupole LC/MS System for forensic analysis of ink pens and markers

In forensics, the analysis of ink writings from documentation is required for authentication or crime analysis. Ten organic ink dye components typically found in ink pens were separated using the Agilent 1290 Infinity LC System and quantified using the Agilent 6140 single quadrupole LC/MS System. The dyes were separated in less than 3.5 min using a sub-2-μm, 30 mm column. Analysis of ink markin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012