Repositionable Versus Balloon‐Expandable Devices for Transcatheter Aortic Valve Implantation in Patients With Aortic Stenosis
نویسندگان
چکیده
BACKGROUND The safety and effectiveness of the fully repositionable LOTUS valve system as compared with the balloon-expandable Edwards SAPIEN 3 prosthesis for the treatment of aortic stenosis has not been evaluated to date. METHODS AND RESULTS All patients undergoing transcatheter aortic valve implantation with the Edwards SAPIEN 3 or the LOTUS valve system were included into the Swiss Transcatheter Aortic Valve Implantation Registry. An adjusted analysis was performed to compare the early clinical safety outcome according to the Valve Academic Research Consortium-2 definition. Between February 2014 and September 2015, 140 and 815 patients were treated with the LOTUS and the Edwards SAPIEN 3 valve, respectively. There was no difference in crude and adjusted analyses of the early safety outcome between patients treated with LOTUS (14.3%) and those treated with Edwards SAPIEN 3 (14.6%) (crude hazard ratio, 0.97; 95% CI, 0.61-1.56 [P=0.915]; adjusted hazard ratio, 1.03; 95% CI, 0.64-1.67 [P=0.909]). More than mild aortic regurgitation was <2% for both devices. A total of 34.3% of patients treated with LOTUS and 14.1% of patients treated with Edwards SAPIEN 3 required a permanent pacemaker (HR, 2.76; 95% CI, 1.97-3.87 [P<0.001]). CONCLUSIONS The repositionable LOTUS valve system and the balloon-expandable Edwards SAPIEN 3 prosthesis appeared comparable in regard to the Valve Academic Research Consortium-2 early safety outcome, and the rates of more than mild aortic regurgitation were exceedingly low for both devices. The need for new permanent pacemaker implantation was more frequent among patients treated with the LOTUS valve.
منابع مشابه
Options for transcatheter aortic valve implantation: comparing self-expanding with balloon- expandable valves
Options for transcatheter aortic valve implantation: comparing self-expanding with balloonexpandable valves The advent of transcatheter aortic valve implantation (TAVI) has offered clinicians the option of managing patients with severe symptomatic aortic stenosis, who are at high operative risk, the possibility of replacing the aortic valve without requiring a full open-heart surgery. Two techn...
متن کاملFrom CoreValve to Evolut PRO: Reviewing the Journey of Self-Expanding Transcatheter Aortic Valves
Transcatheter aortic valve replacement (TAVR) has become standard therapy for patients with severe aortic stenosis who are deemed at least intermediate risk for surgical valve replacement. Over the past decade, several technological advances have taken place to improve the quality and safety of these devices. The current commercially available valves are broadly grouped into balloon expandable ...
متن کاملTranscatheter aortic valve implantation with balloonexpandable valve: early experience from China
OBJECTIVE The aim of the current study was to evaluate the early experience of the application of transcatheter aortic valve implantation with the balloon-expandable system in China. The transcatheter aortic valve implantation technology has been widely used for patients with inoperable severe aortic stenosis in the developed world. The application of transcatheter aortic valve implantation is ...
متن کامل1-Year Outcomes After Transcatheter Aortic Valve Replacement With Balloon-Expandable Versus Self-Expandable Valves: Results From the CHOICE Randomized Clinical Trial.
BACKGROUND The use of a balloon-expandable transcatheter heart valve previously resulted in a greater rate of device success compared with a self-expandable transcatheter heart valve. OBJECTIVES The aim of this study was to evaluate clinical and echocardiographic outcome data at longer term follow-up. METHODS The investigator-initiated trial randomized 241 high-risk patients with symptomati...
متن کاملEarly versus newer generation devices for transcatheter aortic valve implantation in routine clinical practice: a propensity score matched analysis
Aim Contemporary data comparing early versus newer generation transcatheter heart valve (THV) devices in routine clinical practice are lacking. We sought to compare the safety and efficacy of early versus newer generation THVs in unselected patients undergoing transcatheter aortic valve implantation (TAVI). Methods and results We performed a propensity score matched analysis of patients under...
متن کامل