Peracetic acid-ethanol treatment of allogeneic avital bone tissue transplants--a reliable sterilization method.
نویسندگان
چکیده
OBJECTIVES Based on the European Standard EN 1040, the validation guidelines of the German Federal Institute for Drugs and Medical Devices and CPMP guidelines we tested the antimicrobial effectiveness of a peracetic acid-ethanol sterilization procedure (PES) in allogenic avital bone transplants. STUDY DESIGN Delipidated human bone spongiosa cubes (15 x 15 x 15 mm) served as tissue. Three enveloped viruses (human immunodeficiency virus type 2, pseudorabies virus, bovine virus diarrhoea virus) and three non-enveloped viruses (hepatitis A virus, poliovirus, porcine parvovirus) were used. The reduction of virus infectivity was measured as TCID50/ml in neutralized supernatants and bone homogenates. Staphylococcus aureus. Enterococcus faecium, Pseudomonas aeruginosa. Bacillus subtilis. Clostridium sporogenes, Mycobacterium terrae. Candida albicans, Aspergillus niger as well as spores of Bacillus subtilis were tested additionally. PES led to a reduction of virus titres by more than 4 log10. Only HAV showed a reduction below 4 log10 (2.87) with residual infectivity. After including a delipidating step for HAV-infected cells, a reduction of over 7 log10 HAV titre was found. For viable bacteria, fungi and spores a titre reduction below the detection level (5 log10) was achieved after an incubation time of 2 hours. CONCLUSIONS The peracetic acid-ethanol procedure proved to be a reliable method for the sterilization of human bone transplants (layer thickness < or = 15 mm). However, additional safety measures (anamnestic informations, infectious serology, HIV-/HBV-/HCV-PCR in case of multiorgan donors) should be taken.
منابع مشابه
Effects of common sterilization methods on the structure and properties of poly(D,L lactic-co-glycolic acid) scaffolds.
While methods for the production of scaffolds with the appropriate mechanical properties and architecture for tissue engineering are attracting much attention, the effects of subsequent sterilization processes on the scaffold properties have often been overlooked. This study sought to determine the effects of sterilization with ethanol, peracetic acid, ultraviolet irradiation, and antibiotic so...
متن کاملComparative Biomechanical and Microstructural Analysis of Native versus Peracetic Acid-Ethanol Treated Cancellous Bone Graft
Bone transplantation is frequently used for the treatment of large osseous defects. The availability of autologous bone grafts as the current biological gold standard is limited and there is a risk of donor site morbidity. Allogenic bone grafts are an appealing alternative, but disinfection should be considered to reduce transmission of infection disorders. Peracetic acid-ethanol (PE) treatment...
متن کاملPeracetic acid: a practical agent for sterilizing heat-labile polymeric tissue-engineering scaffolds.
Advanced biomaterials and sophisticated processing technologies aim at fabricating tissue-engineering scaffolds that can predictably interact within a biological environment at the cellular level. Sterilization of such scaffolds is at the core of patient safety and is an important regulatory issue that needs to be addressed before clinical translation. In addition, it is crucial that meticulous...
متن کاملVaporized Peracetic Acid (vpa) Sterilization
M in ne ap ol is , M N 5 54 47 VAPORIZED PERACETIC ACID (VPA) STERILIZATION Peracetic Acid as a Biocide REVOXTM sterilization technology uses a room temperature vapor composed of three active compounds; hydrogen peroxide (H2O2), acetic acid and peracetic acid (PAA). PAA is formed by the reaction of acetic acid and H2O2 with the addition of a catalyst; these compounds exist in equilibrium and th...
متن کاملSterilizing elastomeric chains without losing mechanical properties. Is it possible?
OBJECTIVE To investigate the effects of different sterilization/disinfection methods on the mechanical properties of orthodontic elastomeric chains. METHODS Segments of elastomeric chains with 5 links each were sent for sterilization by cobalt 60 (Co60) (20 KGy) gamma ray technology. After the procedure, the elastomeric chains were contaminated with clinical samples of Streptococcus mutans. S...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Annals of transplantation
دوره 8 2 شماره
صفحات -
تاریخ انتشار 2003