Implant/abutment vertical misfit of one-piece cast frameworks made with different materials.

نویسندگان

  • Gustavo Augusto Seabra Barbosa
  • Flávio Domingues das Neves
  • Maria da Gloria Chiarello de Mattos
  • Renata Cristina Silveira Rodrigues
  • Ricardo Faria Ribeiro
چکیده

This study compared vertical and passive fit of one-piece cast frameworks made with 3 different materials: commercially pure titanium (CP Ti - G1), cobalt-chromium alloy (Co-Cr - G2) and nickel-chromium-titanium alloy (Ni-Cr-Ti - G3). Fifteen frameworks were obtained simulating bars for fixed prosthesis in a model with 5 implants. The passive and vertical fit of the framework interface was measured using an optical microscope at x30 magnification. Data were statistically analyzed by ANOVA and LSD tests (α=0.05). Mean and standard deviation values for passive fit and vertical fit were, respectively: G1 [472.49 (109.88) µm and 29.9 (13.24) µm], G2 [584.84 (120.20) µm and 27.05 (10.30) µm], and G3 [462.70 (179.18) µm and 24.95 (11.14) µm]. For vertical fit, there were no significant differences among G1, G2 and G3 (p=0.285). There were no significant differences for passive fit between G1 and G3 (p=0.844), but both differed significantly from G2 (p=0.028 and p=0.035, respectively), which showed the highest misfit values. It may be concluded that the vertical fit of frameworks was not affected by the tested materials, and that one-piece cast frameworks resulted in inadequate passive fit. The Co-Cr alloy presented the worst values for passive fit.

منابع مشابه

Fit Analysis of Different Framework Fabrication Techniques for Implant-Supported Partial Prostheses.

PURPOSE This study evaluated the vertical misfit of implant-supported frameworks made using different techniques to obtain passive fit. MATERIALS AND METHODS Thirty three-unit fixed partial dentures were fabricated in cobalt-chromium alloy (n = 10) using three fabrication methods: one-piece casting, framework cemented on prepared abutments, and laser welding. The vertical misfit between the f...

متن کامل

Prosthetic misfit of implant-supported prosthesis obtained by an alternative section method

PURPOSE Adequate passive-fitting of one-piece cast 3-element implant-supported frameworks is hard to achieve. This short communication aims to present an alternative method for section of one-piece cast frameworks and for casting implant-supported frameworks. MATERIALS AND METHODS Three-unit implant-supported nickel-chromium (Ni-Cr) frameworks were tested for vertical misfit (n = 6). The fram...

متن کامل

Relation between implant/abutment vertical misfit and torque loss of abutment screws.

This study investigated whether there is a direct correlation between the level of vertical misfit at the abutment/implant interface and torque losses (detorque) in abutment screws. A work model was obtained from a metal matrix with five 3.75 x 9 mm external hex implants with standard platform (4.1 mm). Four frameworks were waxed using UCLA type abutments and one-piece cast in commercially pure...

متن کامل

Effect of Vertical Misfit on Screw Joint Stability of Implant-Supported Crowns

The passive fit between prosthesis and implant is a relevant factor for screw joint stability and treatment success. The aim of this study was to evaluate the influence of vertical misfit in abutment-implant interface on preload maintenance of retention screw of implant-supported crowns. The crowns were fabricated with different abutments and veneering materials and divided into 5 groups (n = 1...

متن کامل

مقایسه تشخیص رادیوگرافیک عدم تطابق اباتمنت‌‌های زیرکونیایی و تیتانیومی در سه نوع مختلف ناحیه اتصال

Background and Aims: In response to esthetic demand and use of zirconia abutments; detection of implant-abutment connection misfit is so important. The purpose of this study was to evaluate the sensitivity and specificity of radiographic images in the detection of abutment-implant connection misfit in zirconia and titanium abutments of three different implant connections. Materials and Met...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

متن کامل
عنوان ژورنال:
  • Brazilian dental journal

دوره 21 6  شماره 

صفحات  -

تاریخ انتشار 2010