Coronal shear fracture of the humeral trochlea.

نویسندگان

  • Ramesh Kumar Sen
  • Sujit Kumar Tripahty
  • Tarun Goyal
  • Sameer Aggarwal
چکیده

PURPOSE To review records of 5 patients with anterior coronal trochlear fractures. METHODS Four men and one woman aged 25 to 46 (mean, 34) years underwent cancellous screw (n=3) or Kirschner wire (n=2) fixation for anterior coronal fractures of the humeral trochlea after falling on a flexed elbow. Patients were operated on through a medial approach. Three patients who had a large osteochondral fragment underwent fixation using 4-mm AO partially threaded cancellous screws. Two patients who had a small un-amenable osteochondral fragment (with articular cartilage damage) underwent fixation using Kirschner wires. Patients were evaluated using the Mayo Elbow Performance Index (MEPI) based on pain, arc of motion, stability, and functional disability. RESULTS The mean time from injury to surgery was 7 (range, 5-10) days. The mean follow-up period was 2.7 years. No patient had any wound-related problems, postoperative neurovascular compromise, or avascular necrosis. Radiographic union was noted after a mean of 14 weeks. Outcome was excellent in 4 patients and good in one. The mean arc of flexion-extension was 101º and the mean arc of supination-pronation was 130º. The mean MEPI was 92. The MEPI was relatively low in the 2 patients with a small osteochondral fragment who underwent Kirschner wire fixation. One patient with articular cartilage damage developed mild degenerative changes and had to change his occupation. The remaining 4 patients were pain-free and had returned to their occupations within 4 months. CONCLUSION Open reduction and screw fixation restores articular congruency and enables early mobilisation. Small coronal shear fractures of the trochlea not amenable to screw fixation should be fixed with Kirschner wires.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of coronal shear fractures of the distal humerus on elbow kinematics and stability.

BACKGROUND Coronal shear fractures of the distal humerus can include some or all of the cartilaginous and bony surface. Fixation is preferred, but severe comminution, nonunion, and avascular necrosis may mandate excision. The amount of distal humerus that is safe to excise is unknown. This study examined the effect of excision of the capitellum and trochlea on elbow kinematics and stability wit...

متن کامل

Retrospective analysis of open reduction and internal fixation of coronal plane fractures of the capitellum and trochlea using the anterolateral approach

INTRODUCTION Coronal plane distal humeral injuries are relatively rare. Numerous classification systems have been proposed as the complexity of these fractures has been realized. We in the present series of ten patients describe the surgical technique of Open Reduction and Internal Fixation of Coronal plane fractures of the distal humerus with headless compression screws performed using the ant...

متن کامل

Regarding "Large coronal shear fractures of the capitellum and trochlea treated with headless compression screws".

BACKGROUND The purpose of this study is to retrospectively evaluate the clinical outcomes of 18 patients with large coronal shear fractures of the capitellum and lateral trochlea that underwent open reduction and internal fixation with headless compression screws. METHODS Eighteen patients were identified (16 women, 2 men) with an average age of 45 years and an average follow-up of 26 months....

متن کامل

Management of isolated coronal shear fractures of the humeral capitellum with Herbert screw fixation through anterolateral approach

BACKGROUND Due to the intraarticular and complex nature of the coronal shear fracture of the humeral capitellum and its rarity, it has been difficult to formulate a universally accepted method of surgical management. The purpose of this study is to retrospectively evaluate the clinical outcomes of 15 patients with isolated coronal shear fractures of the capitellum treated by Herbert screw fixat...

متن کامل

A Pitfall in Fixation of Distal Humeral Fractures with Pre-Contoured Locking Compression Plate

Anatomically precontoured locking plates are intended to facilitate the fixation of articular fractures and particularly those associated with osteoporosis. Fractures of the distal humerus are relatively uncommon injuries where operative intervention can be exceptionally challenging. The distal humeral trochlea provides a very narrow anatomical window through which to pass a fixed-angle locking...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of orthopaedic surgery

دوره 21 1  شماره 

صفحات  -

تاریخ انتشار 2013