Assessment of renal volume by three-dimensional ultrasonography in pregnant bitches: an experimental study using virtual organ computer-aided analysis
نویسندگان
چکیده
BACKGROUND To assess and to compare the renal volume evolution in bitches during pregnancy by two-dimensional (2D) ultrasonography using the ellipsoid technique (volume = length x width x depth x 0.523) and three-dimensional (3D) ultrasonography using the Virtual Organ Computer-aided AnaLysis (VOCAL) method. A longitudinal prospective study was performed with 17 normal Golden Retrievers bitches during pregnancy from heat to the last third of gestation. The ultrasound scans were performed by two veterinarians. The left and right kidneys were assessed in three moments (day 0 = non-pregnant bitches; days 1st to 20th of pregnancy and days 21st to 40th of pregnancy) by three techniques (ellipsoid; VOCAL 12° and VOCAL 30°). For reproducibility calculations, we used the intraclass correlation coefficient (ICC). RESULTS The inferential result of the volumes in ANOVA revealed the interaction effect between side and moment (p = 0.009). The 3D techniques showed, in average, the same renal volumes (p = 0.137) regardless of the side and moment. Considering the right side, the renal volume in the day 0 was smaller than the day 21st to 40th (p = 0.029). Considering the left side, the renal volume at day 0 was smaller than the day 1st to 20th (p = 0.020) and day 21st to 40th (p = 0.007). It was found good intra observer reproducibility (ICC > 0.9) and none of the three techniques showed a good inter observer reproducibility (ICC < 0.7). CONCLUSION The renal volume bitches by 3D ultrasonography using the VOCAL method (12° and 30°) had good correlation with the volume obtained by 2D ultrasonography method.
منابع مشابه
Efficacy of fetal thigh volumetry in predicting birth weight using the virtual organ computer-aided analysis (VOCAL) technique.
OBJECTIVES The present study was conducted to compare the accuracy of formulas used to calculate fetal thigh volume (FTV) using the virtual organ computer-aided analysis (VOCAL) technique with two-dimensional (2D) in formulas predicting birth weight. MATERIALS AND METHODS This was a prospective, cross-sectional study of 84 pregnant women with 72 hours of delivery evaluated at a university hos...
متن کاملValidation of 3D power Doppler and VOCAL software in the sonographic assessment of hepatic venous flow
UNLABELLED AIM To evaluate the reproducibility of three-dimensional power Doppler ultrasonography (3D-PDU) and the repeatability of Virtual Organ Computer-aided AnaLysis (VOCAL) software in the assessment of hepatic venous flow in ten healthy non-pregnant individuals. METHODS Visualization of hepatic veins was performed using both intra- and subhepatic approaches; These examinations were ...
متن کاملReproducibility of fetal limbs volume by three- dimensional ultrasonography utilizing the XI VOCAL method*
OBJECTIVE: To assess the reproducibility of fetal thigh and upper arm volumes measurement by threedimensional ultrasonography utilizing the eXtended Imaging Virtual Organ Computer-aided AnaLysis (XI VOCAL) method. MATERIALS AND METHODS: This reproducibility study enrolled 43 pregnant women with healthy singleton pregnancies between 20 and 37 gestational weeks. The XI VOCAL 10 planes was the met...
متن کاملEstimation of placental volume by three-dimensional ultrasonography with the XI VOCAL method in the first gestational trimester*
OBJECTIVE: To determine reference values for placental volume at 7 to 10 + 6 weeks of gestation by means of three-dimensional ultrasonography with the XI VOCAL (eXtended Imaging Virtual Organ Computer-aided Analysis) method. MATERIALS AND METHODS: A cross-sectional study was developed with 70 pregnant women at 7 to 10 + 6 weeks of gestation. The XI VOCAL method with ten sequential adjacent plan...
متن کاملThree-dimensional ultrasonographic bladder volume measurement: reliability of the Virtual Organ Computer-Aided Analysis technique using different rotation steps.
OBJECTIVE The purpose of this study was to investigate the reliability of Virtual Organ Computer-Aided Analysis (VOCAL; GE Healthcare, Kretztechnik, Zipf, Austria) using the 4 standard rotation steps to measure the bladder volume with 3-dimensional (3D) ultrasonography. METHODS Using the 4 standard rotation steps of VOCAL, 2 independent observers made 3D volume measurement data sets from the ...
متن کامل