Iterative sorting for four-dimensional CT images based on internal anatomy motion.
نویسندگان
چکیده
Current four-dimensional (4D) computed tomography (CT) imaging techniques using multislice CT scanners require retrospective sorting of the reconstructed two-dimensional (2D) CT images. Most existing sorting methods depend on externally monitored breathing signals recorded by extra instruments. External signals may not always accurately capture the breathing status and may lead to severe discontinuity artifacts in the sorted CT volumes. This article describes a method to find the temporal correspondences for the free-breathing multislice CT images acquired at different table positions based on internal anatomy movement. The algorithm iteratively sorts the CT images using estimated internal motion indices. It starts from two imperfect reference volumes obtained from the unsorted CT images; then, in each iteration, thorax motion is estimated from the reference volumes and the free-breathing CT images. Based on the estimated motion, the breathing indices as well as the reference volumes are refined and fed into the next iteration. The algorithm terminates when two successive iterations attain the same sorted reference volumes. In three out of five patient studies, our method attained comparable image quality with that using external breathing signals. For the other two patient studies, where the external signals poorly reflected the internal motion, the proposed method significantly improved the sorted 4D CT volumes, albeit with greater computation time.
منابع مشابه
Phase versus amplitude sorting of 4D‐CT data
Image quality of CT scans suffers when objects undergo motion. Respiratory motion causes artifacts, which prevents adequate visualization of anatomy. Four-dimensional CT (4D-CT) is a method in which image reconstruction of moving objects is retrospectively gated according to the recorded phase information of the monitored motion pattern. Although several groups have investigated the use of 4D-C...
متن کاملAnalysis of 4D CT cine images for the characterization of organ motion due to breathing
A semi-automatic procedure to correlate the motion of lung tumor points in 4D-CT images with a respiratory surrogate signal is presented. Data analysis was performed to characterize of the robustness of external/internal correlation properties in the clinical framework of gated radiotherapy treatments. A cross-correlation based algorithm was implemented to perform template matching for tracking...
متن کاملLung Deformation Estimation and Four-dimensional CT Lung Reconstruction1
Rationale and Objectives. Four-dimensional (4D) computed tomography (CT) can be used in radiation treatment planning to account for respiratory motion. Current 4D CT techniques have limitations in either spatial or temporal resolution. In addition, most of these techniques rely on auxiliary surrogates to relate the time of the CT scan to the patient’s respiratory phase. We propose a 4D CT metho...
متن کاملA generalized framework unifying image registration and respiratory motion models and incorporating image reconstruction, for partial image data or full images
Surrogate-driven respiratory motion models relate the motion of the internal anatomy to easily acquired respiratory surrogate signals, such as the motion of the skin surface. They are usually built by first using image registration to determine the motion from a number of dynamic images, and then fitting a correspondence model relating the motion to the surrogate signals. In this paper we prese...
متن کاملGross tumor volume dependency on phase sorting methods of four-dimensional computed tomography images for lung cancer
PURPOSE To see the gross tumor volume (GTV) dependency according to the phase selection and reconstruction methods, we measured and analyzed the changes of tumor volume and motion at each phase in 20 cases with lung cancer patients who underwent image-guided radiotherapy. MATERIALS AND METHODS We retrospectively analyzed four-dimensional computed tomography (4D-CT) images in 20 cases of 19 pa...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Medical physics
دوره 35 3 شماره
صفحات -
تاریخ انتشار 2008