Two-dimensional echocardiographic findings in double orifice mitral valve.
نویسندگان
چکیده
Between December 1981 and April 1984, five children ranging in age from 1 month to 5 1/2 years examined by two-dimensional echocardiography appeared to have a double orifice mitral valve. The diagnosis was verified in one patient at surgery, one patient by angiography and one patient by necropsy. Associated malformations included mitral stenosis and regurgitation, coarctation of the aorta, ostium primum and secundum atrial septal defect, ventricular septal defect and hypoplastic left heart syndrome. Three varieties of double orifice mitral valve were observed: an incomplete bridge type (one patient), in which a small strand of tissue connected the anterior and posterior leaflets at the leaflet edge level; a complete bridge type (three patients), in which a fibrous bridge divided the atrioventricular orifice completely into equal or unequal parts and a hole type (one patient), in which an additional orifice with subvalvular apparatus occurred in the posterior commissure of the mitral valve. These three types could be distinguished by sweeping the transducer in cross-sectional view from the apex toward the base of the heart. Both orifices could be seen throughout the scan in the complete bridge type while in the incomplete bridge type the two orifices could be seen only at the level of the papillary muscles. In the hole type, the second orifice was seen at about midleaflet level. In all three types, the chordae surrounding each orifice attached to only one papillary muscle. Congenital mitral stenosis or regurgitation was evident in three patients. The type of the double orifice mitral valve did not predict the presence or severity of symptoms.
منابع مشابه
Two-dimensional echocardiography in double orifice mitral valve.
In a patient with endocarditis and significant aortic insufficiency, two-dimensional echocardiography revealed an abnormal mitral valve configuration with division of the valve into two separate orifices. At autopsy, a double orifice mitral valve with two sets of valve leaflets was observed. Appreciation of this echocardiographic abnormality is important because double orifice mitral valve is a...
متن کاملEffect of position on echocardiographic diagnosis of mitral valve prolapse
Echocardiography has been accepted as the diagnostic modality of choice for mitral valve prolapse (MVP). The determine the effect of position on echocardiographic diagnosis of MVP, we examined 693 consecutive patients referred to the echocardiography laboratory because of suspected MVP. First, patients were examined using the usual standard M-Mode echocardiography( left parasternal third or fou...
متن کاملDouble-orifice mitral valve - echocardiographic findings.
BACKGROUND Double-orifice mitral valve (DOMV) is a rare congenital malformation characterised by the presence of two orifices in the left atrio-ventricular valve area, each having an independent chordal attachment to the papillary muscle. AIM To establish the echocardiographic features and incidence of DOMV in patients undergoing an echo study in a tertiary referral centre. METHODS We carri...
متن کاملThree-dimensional echocardiographic imaging of double-orifice mitral valve determining severe mitral stenosis: diagnosis and intraoperative aspect of a very rare clinical entity.
CARDIOVASCULAR FLASHLIGHT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . doi:10.1093/eurheartj/ehr...
متن کاملEvaluation of Björk-Shiley prosthetic valves by real-time two-dimensional Doppler echocardiographic flow mapping.
We studied the value of two-dimensional Doppler echocardiographic color flow mapping for identifying normal transvalve flow profiles and valve malfunction in 20 patients with Björk-Shiley prosthetic valves. Seven patients had Björk-Shiley prosthetic valves in the aortic position alone, seven in the mitral position, and six had prosthetic valves in both the aortic and mitral positions. In 10 pat...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of the American College of Cardiology
دوره 6 2 شماره
صفحات -
تاریخ انتشار 1985