Improvement of plasma lipoprotein profiles during high-flux dialysis.
نویسندگان
چکیده
Patients undergoing maintenance hemodialysis therapy have increased mortality due to cardiovascular disease. One possible etiologic factor for this increased mortality is the lipid abnormalities associated with chronic renal failure. These include elevated triglyceride (TG) and decreased high-density lipoprotein (HDL) concentrations. Lipoprotein profiles of patients undergoing chronic hemodialysis with either saponified cellulose ester (CE) (N = 9) or polysulfone (PS) high-flux dialysis membranes (N = 10) were compared. Patients in each group received similar amounts of heparin during the dialysis. CE-dialyzed patients showed no alteration in serum TG, HDL, low-density lipoprotein, or total cholesterol when predialysis and postdialysis values were compared. PS patients, on the other hand, had a significant decrease in TG concentrations (P < 0.01) as well as a significant rise in HDL (P < 0.01). These changes might signify activation of lipoprotein lipase (LPL) during dialysis. LPL activity in PS sera was significantly greater than LPL in CE sera. Moreover, sera from PS patients inhibited LPL much less than did sera from CE patients. These findings suggest that a circulating substance not dialyzable with cellulosic membranes inhibits LPL in uremic subjects and is removed during dialysis with a PS membrane. Alternatively, the greater biocompatibility of PS may produce less LPL inhibitory cytokines during dialysis. The improvement of lipoprotein profiles in patients receiving dialysis with PS membranes may, in the long term, lead to less morbidity and mortality from atherosclerotic disease.
منابع مشابه
Effects of two low-flux cellulose acetate dialysers on plasma lipids and lipoproteins--a cross-over trial.
BACKGROUND Studies have shown a beneficial effect of high-flux dialysis on lipids, lipoproteins and lipoprotein lipase (Lpl) activity. This has been attributed to improved clearance of Lpl-inhibitory molecules of middle molecular weight, but differences in flux or biocompatibility have not been addressed. We conducted a blinded cross-over trial of two cellulose acetate dialysers (AN140, Althin ...
متن کاملEffect of dialyser membrane pore size on plasma homocysteine levels in haemodialysis patients.
BACKGROUND Hyperhomocysteinaemia is a putative risk factor for atherothrombotic cardiovascular disease in the haemodialysis population. High-dose vitamin B therapy does not entirely normalize elevated plasma total homocysteine (tHcy) levels in haemodialysis patients. Alternative therapies to reduce tHcy further are therefore required. Modifications of the dialysis regimen may result in a better...
متن کاملEvaluation of Oxidative Stress in Blood During Hemodialysis
The number of patients with end-stage renal disease is growing rapidly in Asia. Patients with end stage renal disease failure (ESRD) undergoing long term hemodialysis (HD) are at risk for high oxidative stress. There is paucity of information with regard to oxidative stress during HD. Therefore, the aim of the present study was to evaluate catalase enzyme activity in erythrocytes and the total ...
متن کاملEffect of dialysis flux and membrane material on dyslipidaemia and inflammation in haemodialysis patients.
BACKGROUND Dyslipidaemia, inflammation and oxidative stress are prominent risk factors that potentially cause vascular disease in haemodialysis patients. Dialysis modalities affect uraemic dyslipidaemia, possibly by modifying oxidative stress, but the effects of dialyser flux and membrane material on atherogenic remnant particles and oxidized low-density lipoproteins (LDL) are unknown. METHOD...
متن کاملEnhancement of Toxic Substances Clearance from Blood Equvalent Solution and Human Whole Blood through High Flux Dialyzer by 1 MHz Ultrasound
Background: Hemodialysis is a process of removing waste and excess fluid from blood when kidneys cannot function efficiently. It often involves diverting blood to the filter of the dialysis machin to be cleared of toxic substances. Fouling of pores in dialysis membrane caused by adhesion of plasma protein and other toxins will reduce the efficacy of the filtre.Objective: In This study, the infl...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of the American Society of Nephrology : JASN
دوره 3 7 شماره
صفحات -
تاریخ انتشار 1993