Transcatheter closure of patent foramen ovale using the Amplatzer septal occluder to prevent recurrence of neurological decompression illness in divers.

نویسندگان

  • K P Walsh
  • P T Wilmshurst
  • W L Morrison
چکیده

OBJECTIVE Large flap valve patent foramens may cause paradoxical thromboembolism and neurological decompression illness in divers. The ability of a self expanding Nitinol wire mesh device (Amplatzer septal occluder) to produce complete closure of the patent foramen ovale was assessed. PATIENTS Seven adults, aged 18-60 years, who had experienced neurological decompression illness related to diving. Six appeared to have a normal atrial septum on transthoracic echocardiography, while one was found to have an aneurysm of the interatrial septum. METHODS Right atrial angiography was performed to delineate the morphology of the right to left shunt. The defects were sized bidirectionally with a precalibrated balloon filled with dilute contrast. The largest balloon diameter that could be repeatedly passed across the septum was used to select the occlusion device diameter. Devices were introduced through 7 F long sheaths. All patients underwent transthoracic contrast echocardiography one month after the implant. RESULTS Device placement was successful in all patients. Device sizes ranged from 9-14 mm. The patient with an aneurysm of the interatrial septum had three defects, which were closed with two devices. Right atrial angiography showed complete immediate closure in all patients. Median (range) fluoroscopy time was 13.7 (6-35) minutes. Follow up contrast echocardiography showed no right to left shunting in six of seven patients and the passage of a few bubbles in one patient. All patients have been allowed to return to diving. CONCLUSION The Amplatzer septal occluder can close the large flap valve patent foramen ovale in divers who have experienced neurological decompression illness. Interatrial septal aneurysms with multiple defects may require more than one device.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of the geometric profile of the Amplatzer and Cardioseal septal occluders by three dimensional echocardiography.

OBJECTIVE To apply three dimensional echocardiography to describe the geometric profile of the Amplatzer and Cardioseal occluders after deployment for closure of atrial septal defect. METHODS 20 patients (mean (SD) age, 14 (5) years) were enrolled for transcatheter closure of a secundum atrial septal defect with the Amplatzer occluder (10) or with the Cardioseal occluder (10). The two populat...

متن کامل

Long-term follow-up after percutaneous closure of patent foramen ovale with Amplatzer PFO Occluder: a single center experience.

INTRODUCTION Patent foramen ovale (PFO) is associated with the occurrence of cryptogenic strokes, transient neurological ischemic attacks (TIA) and migraine. Therefore despite the recent ambiguous results of prospective controlled trials, percutaneous closure of PFO is still performed in many centers. AIM To evaluate the safety and effectiveness of percutaneous PFO closure in the prevention o...

متن کامل

Pacemaker lead entrapment complicating transcatheter closure of a patent foramen ovale.

T ranscatheter cardiovascular interventions are nowadays more frequently and safely performed, thus leading to populate the heart with medical devices. Here, we describe an unusual complication following percutaneous closure of a patent foramen ovale (PFO) with an atrial septal occluder. A 52-year-old woman with history of transient ischemic attack was found to have a PFO associated with an atr...

متن کامل

Transcatheter Amplatzer device closure of atrial septal defect and patent foramen ovale in patients with presumed paradoxical embolism.

OBJECTIVE To review our experience with, and profile the safety and efficacy of, the Amplatzer PFO (patent foramen ovale) occluder (APO) and Amplatzer septal occluder (ASO) used to close PFO and/or atrial septal defect (ASD) in patients with paradoxical embolism (PE). PATIENTS AND METHODS Between April 1998 and November 2002, 103 patients at the Mayo Clinic in Rochester, Minn, and Scottsdale,...

متن کامل

Intermediate and Long-Term Results of Transcatheter Closure of Patent Foramen Ovale Using the Amplatzer Patent Foramen Ovale Occluder: One Case of Pulmonary Embolism Irrespective of Patent Foramen Ovale Closure

BACKGROUND AND OBJECTIVES Patent foramen ovale (PFO) has been implicated in the pathogenesis of cryptogenic stroke or transient ischemic attack (TIA) due to paradoxical embolism, and in the pathogenesis of migraine. This paper reports the intermediate and long-term results of transcatheter closure of PFO associated with cerebrovascular accidents (CVAs), TIAs and migraine, using the Amplatzer PF...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Heart

دوره 81 3  شماره 

صفحات  -

تاریخ انتشار 1999