Quantitative analysis of the measuring capabilities of the KT-1000 knee ligament arthrometer.
نویسندگان
چکیده
The KT-1000 arthrometer was evaluated in vitro and in vivo to determine accuracy and quantify effects of potential error sources in clinical application. The KT-1000 arthrometer in vitro accuracy was evaluated by making 30 measurements of 13 known displacements (range, +15 to -15 mm). The effect of applied force on malalignment measurements was evaluated in vitro by making repeated measurements with force applied 5 degrees, 10 degrees, and 15 degrees from the vertical position. The effect of malpositioning the device along the joint line was evaluated in vivo by making repeated measurements 1 cm proximal and 1 cm distal to the joint line. The KT-1000 arthrometer was accurate in vitro (average error, 0.13 mm; SD, 0.12 mm). The range of measurements increased when the angle of force application was increased. Positioning the device 1 cm proximal to the joint line produced larger anterior translation measurements in vivo than those at the joint line (5.8 versus 5.4 mm), while positioning it 1 cm distal produced smaller measurements (4.4 mm). The KT-1000 arthrometer's accuracy indicates great potential for clinical application, but one must ensure that the displacing force is directed properly and the device is positioned accurately over the joint line.
منابع مشابه
Review article: Validity of the KT-1000 knee ligament arthrometer.
The KT-1000 knee arthrometer (KT-1000) is an objective instrument to measure anterior tibial motion relative to the femur for anterior cruciate ligament (ACL) reconstruction. Four studies between 1950 and 2007 regarding validity of the KT-1000 were identified using a Medline search. One had interpretable information on sensitivities, specificities, and predictive values to validate the instrume...
متن کاملIntratester and intertester reliability of the KT-1000 arthrometer in the assessment of posterior laxity of the knee.
We measured tibial translation in the knees of 22 subjects with posterior cruciate ligament tears or reconstructions by using the KT-1000 arthrometer. To assess the reliability of the device, two testers made measurements. One tester was a novice and the second tester had substantial clinical experience with the KT-1000 arthrometer. The quadriceps neutral angle was found for the uninvolved knee...
متن کاملClinical outcomes of anterior cruciate ligament reconstruction using LARS artificial graft with an at least 7-year follow-up
The aim of our study was to assess the medium-term clinical outcomes of anterior cruciate ligament (ACL) reconstruction using the Ligament Advanced Reinforcement System (LARS) artificial ligament.A total of 168 patients who underwent arthroscopic ACL reconstruction with the LARS artificial ligament in our department were enrolled in our research. Only 125 met the inclusion/exclusion criteria, a...
متن کاملMeasurement of the tibial anterior-posterior translation for Lachman test in the awake state and under anesthesia using electromagnetic measurement system.
Introduction: Anterior cruciate ligament (ACL) deficiency causes an increase in anterior tibial translation. To assess the amount of the anterior-posterior tibial translation, KT-arthorometer has been widely used. However it has been suggested by some reports that the practical reliability of the KT-1000 arthrometer measurement is doubted due to the interand intra-examiner errors. The Lachman t...
متن کاملارزیابی نتایج بالینی روش مدیالیزه کردن ورودی تونل تیبیا در بازسازی لیگامان صلیبی قدامی
Introduction: Purpose of this study was to evaluate outcome of Anterior Cruciate Ligament (ACL) reconstruction surgery with a medial tibia tunnel entrance in patients with rupture of the ligament. Methods: This cross-sectional study was performed in patients admitted to Sina Hospital in Tehran from April 2009 to April 2011. ACL reconstruction was done by arthroscopic surgery and the patients ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The American journal of sports medicine
دوره 21 5 شماره
صفحات -
تاریخ انتشار 1993