Complications associated with implantable cardioverter-defibrillator replacement in response to device advisories.

نویسندگان

  • Paul A Gould
  • Andrew D Krahn
چکیده

CONTEXT Recent implantable cardioverter-defibrillator (ICD) advisories and recalls have caused management dilemmas for physicians, particularly because there are no specific guidelines or data on outcomes from current management strategies. The risk of ICD generator replacement has not been assessed in this population. OBJECTIVE To determine the complication rate associated with ICD generator replacement for the current ICD advisories. DESIGN AND SETTING Seventeen ICD implanting centers in Canada were surveyed to assess complication rates as a result of generator replacements because of ICD advisories from October 2004 to October 2005. MAIN OUTCOME MEASURE Complications associated with elective ICD generator replacement for current device advisories. RESULTS At the 17 surveyed centers, 2915 patients had recall devices, including 533 (18.3%) who had advisory ICDs replaced a mean (SD) of 26.5 (11.5) months after their initial implant. Of these patients, 66% had a secondary prevention ICD, and 45% had received a previous appropriate shock. During a mean (SD) of 2.7 (2.8) months' follow-up after ICD generator replacement, complications occurred in 43 patients (8.1%). Major complications attributable to advisory device replacement requiring reoperation occurred in 31 patients (5.8%), with death in 2 patients after extraction for pocket infection. Minor complications occurred in 12 patients (2.3%). There were 3 (0.1%) advisory-related device malfunctions reported, without clinical consequences. CONCLUSIONS ICD generator replacement in patients with advisory devices is associated with a substantial rate of complications, including death. These complications need to be considered in the development of guidelines determining the appropriate treatment of patients with advisory devices.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Implantable cardioverter-defibrillator in a patient with dextrocardia situs inversus

Background: Dextrocardia is a congenital anomaly, which may have coexistent coronary artery disease (CAD), arrhythmias and conventional indications for device therapy. However, the implantation of transvenous leads can be technically challenging and the approach needs to be tailored to the patient's individual anatomy. Case presentation: A 54-year-old male with dextrocardia situs inversus and i...

متن کامل

Arrhythmia/Electrophysiology Complication Rates Associated With Pacemaker or Implantable Cardioverter-Defibrillator Generator Replacements and Upgrade Procedures Results From the REPLACE Registry

Background—Prospective studies defining the risk associated with pacemaker or implantable cardioverter-defibrillator replacement surgeries do not exist. These procedures are generally considered low risk despite results from recent retrospective series reporting higher rates. Methods and Results—We prospectively assessed predefined procedure-related complication rates associated with elective p...

متن کامل

Complication rates associated with pacemaker or implantable cardioverter-defibrillator generator replacements and upgrade procedures: results from the REPLACE registry.

BACKGROUND Prospective studies defining the risk associated with pacemaker or implantable cardioverter-defibrillator replacement surgeries do not exist. These procedures are generally considered low risk despite results from recent retrospective series reporting higher rates. METHODS AND RESULTS We prospectively assessed predefined procedure-related complication rates associated with elective...

متن کامل

THE EFFECT OF NURSE-PEER-LED SUPPORT INTERVENTION ON QUALITY OF LIFE IN PATIENTS WITH AN IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR: A RANDOMIZED CLINICAL TRIAL

Background & Aims: Nowadays, the quality of life and how coping and treatment of patients with an implantable cardiac defibrillator has led to concern and attempts to reduce or eliminate the problems of these patients in the people who provide health care services. This study aimed to determine the effect of nurse-peer-led support intervention on quality of life in patients with an implantable ...

متن کامل

زندگی با دفیبریلاتور قابل کاشت: یک مطالعه پدیده‌شناسی

  Background & Aim: Implantable Cardioverter Defibrillator is the most effective treatment for cardiac dysrhythmias. Having such life-saving device is the unique experience with important changes in the patient’ life. Understanding of these experiences can lead to success in treatment and follow- up.This study aimed to understand the experiences of patients with Implantable Cardioverter Defibri...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • JAMA

دوره 295 16  شماره 

صفحات  -

تاریخ انتشار 2006