ACS CCD Gains, Full Well Depths, and Linearity up to and Beyond Saturation

نویسنده

  • R. L. Gilliland
چکیده

The CCDs on ACS may both be operated at multiple gain settings. Analysis of calibration and science data is used to establish corrections to the supported HRC GAIN=4 and WFC GAIN=2 values; relative to the default gains decreased values of e-/DN of 1.27% and 0.78% respectively are indicated. Maps of the full well depth at which saturation sets in for both HRC and WFC are provided, both cameras show spatial variations in excess of 10%. When operated with gains that fully sample the full well depth, the CCDs remain perfectly (<0.1% relative count levels) linear to well beyond saturation with simple summation over pixels that have been bled into as a result of over-saturation. Linearity at levels from marginal detection in single exposures, to multiple levels up to saturation, and at multiple levels beyond saturation are presented showing excellent results.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

WFC3 UVIS Full Well Depths, and Linearity Near and Beyond Saturation

Maps of the full well depth at which saturation sets in are provided for the two UVIS CCDs on WFC3. The full well depths show about 10% variation over each CCD ranging from 63-71K on UVIS1 and 67-72K on UVIS2. The standard gain of ∼1.6 e-/DN results in saturation safely being on the CCD rather than in the ADC, and linearity for photometry holds to levels better than 1% generally for UVIS2 to we...

متن کامل

CHIRON CCD detector: tests in March 2011

The CHIRON CCD detector system has been delivered to the telescope in January 2011 with numerous shortcomings which have not allowed its science use. Starting mid-February, P. Moore and M. Bonati worked on the controller. The clocking sequence has been changed, the hardware problem in the lower-right readout channel was diagnosed. The system was configured to read through two amplifiers, upper-...

متن کامل

Specifying the Saturation Point of Advertising Budget Using Ideal Planning Model

The goal of the current study is to determine the optimal level of advertising beyond which advertising expenditure will not be justified by revenues. To achieve the goal first different types of media were rated by experts as to the degree of their importance. Then data ware collected by interviewing the managers and reviewing different media resources. The collected data were then analyze...

متن کامل

Specifying the Saturation Point of Advertising Budget Using Ideal Planning Model

The goal of the current study is to determine the optimal level of advertising beyond which advertising expenditure will not be justified by revenues. To achieve the goal first different types of media were rated by experts as to the degree of their importance. Then data ware collected by interviewing the managers and reviewing different media resources. The collected data were then analyze...

متن کامل

ویژگی های اپیدمیولوژیک و تعیین کننده های مرگ و میر سندرم حاد کرونر در ایران

Abstract Background and purpose: Acute coronary syndrome (ACS) includes ST elevation myocardial infarction (STEMI), non–ST-segment elevation myocardial infarction (NSTEMI), and unstable angina. This study was conducted to determine the characteristics of patients with ACS and determinants of their mortality in Iran. Materials and methods: This study was a hospital-based prospective cohort s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2003