Simultaneous acquisition of gradient echo/spin echo BOLD and perfusion with a separate labeling coil.
نویسندگان
چکیده
Arterial spin labeling-based cerebral blood flow imaging complements blood oxygenation level dependent (BOLD) imaging with a measure that is more quantitative and has better specificity to neuronal activation. Relative to gradient echo BOLD, spin echo BOLD has better spatial specificity because it is less biased to large draining veins. Although there have been many studies comparing simultaneously acquired cerebral blood flow data with gradient echo BOLD data in fMRI, there have been few studies comparing cerebral blood flow with SE BOLD and no study comparing all three. We present a pulse sequence that simultaneously acquires cerebral blood flow data with a separate labeling coil, gradient echo BOLD, and spin echo BOLD images. Simultaneous acquisition avoids interscan variability, allowing more direct assessment and comparison of each contrast's relative specificity and reproducibility. Furthermore, it facilitates studies that may benefit from multiple complementary measures.
منابع مشابه
Multiband multi-echo imaging of simultaneous oxygenation and flow timeseries for resting state connectivity
A novel sequence has been introduced that combines multiband imaging with a multi-echo acquisition for simultaneous high spatial resolution pseudo-continuous arterial spin labeling (ASL) and blood-oxygenation-level dependent (BOLD) echo-planar imaging (MBME ASL/BOLD). Resting-state connectivity in healthy adult subjects was assessed using this sequence. Four echoes were acquired with a multiban...
متن کاملReduced susceptibility effects in perfusion fMRI with single-shot spin-echo EPI acquisitions at 1.5 Tesla.
Arterial spin labeling (ASL) perfusion contrast is not based on susceptibility effects and can therefore be used to study brain function in regions of high static inhomogeneity. As a proof of concept, single-shot spin-echo echo-planar imaging (EPI) acquisition was carried out with a multislice continuous ASL (CASL) method at 1.5T. A bilateral finger tapping paradigm was used in the presence of ...
متن کاملاندازه گیری غیریکنواختی امواج رادیوئی در ام آر آی
Introduction: Non-uniformity is one of the most important parameters affecting MRI images which can lead to harmful effects in the diagnosis and analysis of qualitative and quantitative methods. The present study introduced a method for measuring RF non-homogeneity in MRI systems. Methods and Materials: To verify the uniformity of B0 and B1 fields, a cylindrical phantom with a diameter of 24 c...
متن کاملMultiband multi-echo simultaneous ASL/BOLD for task-induced functional MRI
Typical simultaneous blood oxygenation-level dependent (BOLD) and arterial spin labeling (ASL) sequences acquire two echoes, one perfusion-sensitive and one BOLD-sensitive. However, for ASL, spatial resolution and brain coverage are limited due to the T1 decay of the labeled blood. This study applies a sequence combining a multiband acquisition with four echoes for simultaneous BOLD and pseudo-...
متن کاملCine-ASL: a new arterial spin labeling method for myocardial perfusion mapping in mice using a Cine-FLASH labeling and readout module
This study presents a novel arterial spin labeling method to assess myocardial perfusion in small rodents. An ECG-gated pseudo-continuous labeling approach is combined with simultaneous readout over the cardiac cycle using Cine-FLASH. This method allows shorter acquisition times than the previously used Look-Locker FAIR gradient-echo technique while preserving spatial resolution and robustness ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Magnetic resonance in medicine
دوره 64 6 شماره
صفحات -
تاریخ انتشار 2010