Doppler echocardiographic measurement of flow velocity in the ascending aorta during supine and upright exercise.

نویسندگان

  • P J Daley
  • K B Sagar
  • L S Wann
چکیده

Doppler echocardiography was used to measure stroke volume, peak flow velocity, and acceleration of flow in the ascending aorta in 10 healthy young volunteers during unlimited supine bicycle exercise and upright treadmill exercise. High quality studies were obtained in all subjects through the suprasternal notch acoustic window; there was no appreciable degradation in Doppler signal caused by interference by increased respiration or chest wall motion. Stroke volume index increased from 54 ml/m2 at rest to 63.5 ml/m2 at peak supine exercise and from 38 ml/m2 standing at rest to 63.3 ml/m2 during peak upright exercise. Mean peak flow velocity rose from 0.91 m/s at supine rest to 1.36 m/s during maximum supine exercise. In the upright position mean peak flow velocity increased from 0.75 m/s at rest to 1.39 m/s during maximum exercise. Mean peak velocities were lower in the upright position at rest but were not significantly different at peak exercise. Mean acceleration of flow in the ascending aorta increased from 12.02 m/s2 during supine rest to 21.6 m/s2 during supine exercise and from 10.8 m/s2 at rest on the treadmill to 21.9 m/s2 during peak upright exercise. This study shows that echocardiographic measurement of ascending aortic blood flow by the Doppler technique is feasible even during vigorous exercise; that stroke volume and peak flow velocity at rest are lower in the upright position than in the supine position but equalise at peak exercise; and that acceleration of flow in the ascending aorta is the same in both the supine and upright positions and increases equally at peak exercise in both positions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of stroke volume and cardiac output during exercise: comparison of two-dimensional and Doppler echocardiography, Fick oximetry, and thermodilution.

Simultaneous estimates of cardiac output were made during graded upright maximal exercise in 10 male subjects by means of Doppler velocity spectrum of ascending aortic flow, apical two-dimensional echocardiograms, thermodilution, and Fick oximetry. In 15 subjects, aortic annular and root diameters were measured during similar exercise from parasternal two-dimensional echocardiograms. The linear...

متن کامل

Detection of exercise induced changes in left ventricular performance by Doppler echocardiography.

A study was performed to test the hypothesis that Doppler echocardiographic measurement of ascending aortic blood flow can detect exercise induced changes in left ventricular performance during exercise in patients suspected of having ischaemic heart disease. Acceleration and peak velocity of flow and stroke volume were determined by non-imaging Doppler echocardiography in the suprasternal notc...

متن کامل

Alveolar oxygen uptake and femoral artery blood flow dynamics in upright and supine leg exercise in humans.

We tested the hypothesis that the slower increase in alveolar oxygen uptake (VO2) at the onset of supine, compared with upright, exercise would be accompanied by a slower rate of increase in leg blood flow (LBF). Seven healthy subjects performed transitions from rest to 40-W knee extension exercise in the upright and supine positions. LBF was measured continuously with pulsed and echo Doppler m...

متن کامل

Evaluation of left ventricular function during upright exercise: correlation of exercise Doppler with postexercise two-dimensional echocardiographic results.

The relationship of regional and global left ventricular function to aortic flow dynamics during exercise was determined in 14 normal subjects and 14 patients with coronary artery disease. Doppler and two-dimensional echocardiographic studies were performed before, during, and immediately after an exercise test by the Bruce protocol. Two-dimensional echocardiography was used to determine the ej...

متن کامل

I-46: Obstetrical Doppler

Accurate assessment of gestational age, fetal growth, and the detection of fetal and placental abnormalities are major benefits of sonography. Color Doppler can be used to assist in the identification of vascular architecture, detection of vascular pathology and visualization of blood flow changes associated with physiologic processes and disease states. The clinical applications of obstetrical...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British heart journal

دوره 54 6  شماره 

صفحات  -

تاریخ انتشار 1985