Comparison of diffusion approximation and Monte Carlo based finite element models for simulating thermal responses to laser irradiation in discrete vessels.

نویسندگان

  • Rong Zhang
  • Wim Verkruysse
  • Guillermo Aguilar
  • J Stuart Nelson
چکیده

Both diffusion approximation (DA) and Monte Carlo (MC) models have been used to simulate light distribution in multilayered human skin with or without discrete blood vessels. However, no detailed comparison of the light distribution, heat generation and induced thermal damage between these two models has been done for discrete vessels. Three models were constructed: (1) MC-based finite element method (FEM) model, referred to as MC-FEM; (2) DA-based FEM with simple scaling factors according to chromophore concentrations (SFCC) in the epidermis and vessels, referred to as DA-FEM-SFCC; and (3) DA-FEM with improved scaling factors (ISF) obtained by equalizing the total light energy depositions that are solved from the DA and MC models in the epidermis and vessels, respectively, referred to as DA-FEM-ISF. The results show that DA-FEM-SFCC underestimates the light energy deposition in the epidermis and vessels when compared to MC-FEM. The difference is nonlinearly dependent on wavelength, dermal blood volume fraction, vessel size and depth, etc. Thus, the temperature and damage profiles are also dramatically different. DA-FEM-ISF achieves much better results in calculating heat generation and induced thermal damage when compared to MC-FEM, and has the advantages of both calculation speed and accuracy. The disadvantage is that a multidimensional ISF table is needed for DA-FEM-ISF to be a practical modelling tool.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Studying thermal effects of laser on tissue using implicit finite volume method

In this paper, thermal effects of laser irradiance on biological tissue is investigated using computer simulations. Earlier attempts in this field made use of finite difference and finite element techniques. Here a novel approach is adopted to improve the results. The effect of our implicit approach on the convergence procedure and accuracy of results, with different timing steps, is explor...

متن کامل

Thermal Analysis of Laser Hardening for Different Moving Patterns

Transient thermal field in laser surface hardening treatment of medium carbon steel was analyzed by employing both three-dimensional analytical model and finite element model. In finite element model the laser beam was considered as a moving plane heat flux to establish the temperature rise distribution in the work-piece, while in analytical model laser beam was considered as an internal heat s...

متن کامل

Evaluation of the effect of reservoir length on seismic behavior of concrete gravity dams using Monte Carlo method

In present study, the effect of reservoir length on seismic performance of concrete gravity dam has been investigated. Monte Carlo probabilistic analysis has been used to achieve a sensitivity of the responses to variation of truncated reservoir length in finite element model. The ANSYS software based on finite element method is applied for modeling and analysis. The Pine Flat dam in California...

متن کامل

The response of Geant4 hadronic models to the study of neutrons produced in proton irradiation to the light materials

Neutron is one of the products of the interaction of high energy protons with light nuclei. Using computational Monte Carlo codes, it is possible to calculate and predict the neutron spectrum, neutron flux, and doses by simulating the system. But the use of different hadronic models in this process can influence the results of these calculations. In this research, the response of the four hadro...

متن کامل

Heat Transfer Dynamics during Treatment of Port Wine Stain Birthmarks with Multiple-intermittent Cryogen Spurts and Laser Pulses

Port wine stain (PWS) is a congenital, progressive vascular malformation of human skin. Presently, all PWS patients are treated using single cryogen spurt and single laser pulse exposure (SCS-SLP), which does not produce complete lesion blanching in the vast majority of patients. In this study, the feasibility of applying multiple cryogen spurts intermittently with multiple laser pulse exposure...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physics in medicine and biology

دوره 50 17  شماره 

صفحات  -

تاریخ انتشار 2005