Rapid simultaneous mapping of T2 and T2* by multiple acquisition of spin and gradient echoes using interleaved echo planar imaging (MASAGE-IEPI).

نویسندگان

  • David L Thomas
  • Mark F Lythgoe
  • David G Gadian
  • Roger J Ordidge
چکیده

A new MRI sequence for the rapid simultaneous measurement of T2 and T2* is presented. The technique uses the multiple acquisition of spin and gradient echoes with interleaved echo planar imaging (MASAGE-IEPI). IEPI data sets are sampled during and between a pair of short and long echo time spin echoes, allowing the reconstruction of a set of images with different combinations of T2 and T2* weighting and the calculation of T2 and T2* maps. In the context of neuroimaging, these maps can provide information on cerebral hemodynamics and oxygenation status, either via the deoxyhemoglobin-based BOLD signal or by the effect of exogenous paramagnetic contrast agents. MASAGE-IEPI benefits from the inherent advantages of the IEPI approach, i.e., high time resolution and minimal image distortion, and also has good time efficiency due to the acquisition of multiple image data sets following each excitation pulse. The accuracy of the sequence for the measurement of T2 and T2* is verified on phantoms, and the technique is applied to monitor changing hemodynamics in the rat brain during episodes of hypoxia. Data for the generation of maps of T2 and T2* are acquired with a time resolution of 12 s to accurately define the rapidly changing time course. As increasing emphasis is placed on the role of T2 and T2* in the direct measurement of physiological parameters such as cerebral metabolic rate of oxygen consumption and blood vessel sizes, MASAGE-IEPI offers an efficient method for the measurement of these two important MRI parameters.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

GRASE (gradient- and spin-echo) MR imaging: a new fast clinical imaging technique.

A novel technique of magnetic resonance (MR) imaging, which combines gradient-echo and spin-echo (GRASE) technique, accomplishes T2-weighted multisection imaging in drastically reduced imaging time, currently 24 times faster than spin-echo imaging. The GRASE technique maintains contrast mechanisms, high spatial resolution, and image quality of spin-echo imaging and is compatible with clinical w...

متن کامل

Rapid T2* mapping using interleaved echo planar imaging.

Magnetic resonance imaging methods that are sensitive to T2* are widely used in the study of blood oxygenation changes, most notably in functional studies of the brain. In these studies the signal intensity change in T2*-weighted imaging is related to the coupling of cerebral blood flow and metabolism. Rapid measurement of T2* itself would offer a valuable method to quantify blood oxygenation c...

متن کامل

Comparison the Accuracy of Fetal Brain Extraction from T2-Half-Fourier Acquisition Single-Shot Turbo Spin-Echo (HASTE) MR Image with T2-True Fast Imaging with Steady State Free Precession (TRUFI) MR Image by Level Set Algorithm

Background Access to appropriate images of fetal brain can greatly assist to diagnose of probable abnormalities. The aim of this study was to compare the suitability of T2-True Fast Imaging with Steady State Free Precession (T2-TRUFI), and T2-Half-Fourier Acquisition Single-Shot Turbo Spin-Echo (T2- HASTE( magnetic resonance imaging (MRI) to extract the fetal brain using the level set algorithm...

متن کامل

Supplementary methods and results for ” Decoding the large - scale structure of brain function by classifying mental states across individuals ”

Imaging was performed using a 3T Siemens AG (Erlangen, Germany) Allegra MRI scanner at the UCLA Ahmanson-Lovelace Brain Mapping Center. For all subjects, whole-brain functional imaging was performed using a T2*-weighted echoplanar imaging (EPI) sequence with common parameters [repetition time (TR), 2 s; echo time (TE), 30 ms; flip angle, 90; matrix, 64 x 64; field of view (FOV), 200 mm; slice t...

متن کامل

Detection of focal hepatic lesions with MR imaging: prospective comparison of T2-weighted fast spin-echo with and without fat suppression, T2-weighted breath-hold fast spin-echo, and gadolinium chelate-enhanced 3D gradient-recalled imaging.

OBJECTIVE The purpose of this study was to compare breath-hold three-dimensional (3D) rapid gradient-echo (GRE) MR imaging obtained before and after gadolinium chelate injection with T2-weighted fast spin-echo and T2-weighted breath-hold fast spin-echo (BHFSE) MR imaging in the detection of focal hepatic masses. SUBJECTS AND METHODS Fifty-three patients with 108 focal hepatic masses had, pros...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • NeuroImage

دوره 15 4  شماره 

صفحات  -

تاریخ انتشار 2002