Time-resolved fluorescence aptamer-based sandwich assay for thrombin detection.

نویسندگان

  • Da-Wei Huang
  • Cheng-Gang Niu
  • Pin-Zhu Qin
  • Min Ruan
  • Guang-Min Zeng
چکیده

In the present study, the authors report a novel sensitive method for the detection of thrombin using time-resolved fluorescence sensing platform based on two different thrombin aptamers. The thrombin 15-mer aptamer as a capture probe was covalently attached to the surface of glass slide, and the thrombin 29-mer aptamer was fluorescently labeled as a detection probe. A bifunctional europium complex was used as the fluorescent label. The introduction of thrombin triggers the two different thrombin aptamers and thrombin to form a sandwich structure. The fluorescence intensity is proportional to the thrombin concentration. The present sensing system could provide both a wide linear dynamic range and a low detection limit. The proposed sensing system also presented satisfactory specificity and selectivity. Results showed that thrombin was retained at the aptamer-modified glass surface while nonspecific proteins were removed by rinsing with buffer solution. This approach successfully showed the suitability of aptamers as low molecular weight receptors on glass slides for sensitive and specific protein detection.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Patterned biochemical functionalization improves aptamer-based detection of unlabeled thrombin in a sandwich assay.

Here we propose a platform for the detection of unlabeled human α-thrombin down to the picomolar range in a fluorescence-based aptamer assay. In this concept, thrombin is captured between two different thrombin binding aptamers, TBA1 (15mer) and TBA2 (29mer), each labeled with a specific fluorescent dye. One aptamer is attached to the surface, the second one is in solution and recognizes surfac...

متن کامل

A sensitive strategy for label-free and time-resolved fluorescence assay of thrombin using Tb-complex and unmodified gold nanoparticles.

Gold nanoparticles (GNPs) can effectively differentiate the unfolded and folded aptamer, and quench the fluorescence of terbium ternary complexes (Tb-complexes), thus the authors herein report a sensitive strategy for protein detection, using label-free aptamer, Tb-complexes and GNPs. In the presence of thrombin, the aptamer is inclined to form G-quartet, and the folded aptamer cannot adsorb on...

متن کامل

Development and Optimization of a Thrombin Sandwich Aptamer Microarray

A sandwich microarray employing two distinct aptamers for human thrombin has been optimized for the detection of subnanomolar concentrations of the protein. The aptamer microarray demonstrates high specificity for thrombin, proving that a two-site binding assay with the TBA1 aptamer as capture layer and the TBA2 aptamer as detection layer can ensure great specificity at times and conditions com...

متن کامل

Human Thrombin Detection Through a Sandwich Aptamer Microarray: Interaction Analysis in Solution and in Solid Phase

We have developed an aptamer-based microarray for human thrombin detection exploiting two non-overlapping DNA thrombin aptamers recognizing different exosites of the target protein. The 15-mer aptamer (TBA1) binds the fibrinogen-binding site, whereas the 29-mer aptamer (TBA2) binds the heparin binding domain. Extensive analysis on the complex formation between human thrombin and modified aptame...

متن کامل

Highly specific detection of thrombin using an aptamer-based suspension array and the interaction analysis via microscale thermophoresis.

A novel aptamer-based suspension array detection platform was designed for the sensitive, specific and rapid detection of human α-thrombin as a model. Thrombin was first recognized by a 29-mer biotinylated thrombin-binding aptamer (TBA) in solution. Then 15-mer TBA modified magnetic beads (MBs) captured the former TBA-thrombin to form an aptamer-thrombin-aptamer sandwich complex. The median flu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Talanta

دوره 83 1  شماره 

صفحات  -

تاریخ انتشار 2010