A Comparative Study of the Diagnostic Value of Contrast-Enhanced Breast MR Imaging and Mammography on Patients with BI-RADS 3–5 Microcalcifications
نویسندگان
چکیده
OBJECTIVE To retrospectively investigate the diagnostic value of breast MRI in patients with BI-RADS 3-5 microcalcifications in mammography. METHODS Eighty-four patients with BI-RADS 3-5 microcalcifications on mammography underwent breast MR exams before surgical biopsy with a hookwire position under mammographic guidance. Two radiologists reviewed each lesion with BI-RADS by consensus. The diagnostic value of mammography and MRI was compared. RESULTS Histopathological examination revealed 49 benign lesions and 42 malignant lesions. In the assessments of mammography, 21 lesions (23.1%) were assigned to category 3, 51 lesions (56.0%) to category 4, and 19 lesions (20.9%) to category 5. The area under the receiver operating characteristic(ROC) curve for mammography and MR assessment was 0.844, and 0.945, respectively (p<0.05). In cases of category 3 microcalcifications, the specificity of mammography and MR was 100%, and 95.2% (p = 1.000), respectively. In cases of category 4 microcalcifications, the specificity, PPV and accuracy of mammography was 0%, 45.1% and 45.1%; whereas those for MR was 82.1% (p<0.05), 80.8% (P = 0.003) and 86.3% (p<0.05). All microcalcifications of category 5 were correctly diagnosed by mammography and MR. CONCLUSIONS Breast MRI has the potential to significantly improve the diagnosis of category 4 microcalcifications on mammography. Among mammographic category 4 microcalcifications, about 82% of benign lesions can be degraded to BI-RADS 1∼3 by MRI. However for microcalcifications of category 3 and 5, MR exams do not show significant improvement over mammography.
منابع مشابه
Evaluation of the Role of Dynamic Contrast-Enhanced MR Imaging for Patients with BI-RADS 3–4 Microcalcifications
OBJECTIVE The purpose of study was to prospectively evaluate the diagnostic performance of dynamic contrast-enhanced MR imaging in the differentiation of malignant lesions from benign ones in patients with BI-RADS 3-4 microcalcifications detected by mammography. MATERIALS AND METHODS 93 women with 100 microcalcifications had undergone breast MRI from June 2010 to July 2013. Subsequently, 91 r...
متن کاملMammographic features and correlation with biopsy findings using 11-gauge stereotactic vacuum-assisted breast biopsy (SVABB).
BACKGROUND Mammograms are assigned a BI-RADS (Breast Imaging Reporting and Data System) category, which indicates the level of suspicion for cancer. OBJECTIVES (i) To evaluate the use of BI-RADS categories in a non-academic radiology practice based in a community hospital compared with local radiology private offices; (ii) to determine positive predictive value (PPV), sensitivity and specific...
متن کاملBreast 3 T-MR imaging: indication for stereotactic vacuum-assisted breast biopsy
PURPOSE The purpose of this study was to assess indications for stereotactic vacuum-assisted breast biopsy (SVAB) evaluated by breast 3 T-magnetic resonance (3 T-MR) imaging in patients showing suspicious microcalcifications on mammography and negative ultrasound (US) findings. METHODS AND MATERIALS Fifty-five patients with 55 breast lesions showing suspicious microcalcifications on mammograp...
متن کامل3–5 BI-RADs Microcalcifications: Correlation between MRI and Histological Findings
Purpose. To evaluate the correlation between MRI and histopathological findings in patients with mammographically detected 3-5 BI-RAD (Breast Imaging Reporting And Data Systems) microcalcifications and to allow a better surgical planning. Materials and Method. 62 female Patients (age 50 ± 12) with screening detected 3-5 BI-RAD microcalcifications underwent dynamic 3 T contrast-enhanced breast ...
متن کاملBreast magnetic resonance imaging as a problem-solving modality in mammographic BI-RADS 3 lesions
The probability of a mammographic Breast Imaging Reporting and Data System (BI-RADS) 3 lesion being cancer is considered to be less than 2%. Therefore, the work-up of a mammographic BI-RADS 3 lesion should be biopsy or follow-up mammography after 6 months. However, most patients referred for biopsy have benign disease. Although the negative predictive value (NPV) of magnetic resonance imaging (...
متن کامل