Crystal River, Florida 34428-6708 SUBJECT: CRYSTAL RIVER UNIT 3 - ISSUANCE OF AMENDMENT REGARDING REROLL REPAIR FOR ONCE-THROUGH STEAM GENERATOR TUBING
نویسنده
چکیده
The Commission has issued the enclosed Amendment No. 198 to Facility Operating License No. DPR-72 for Crystal River Unit 3 (CR-3). The amendment consists of changes to the existing Technical Specifications (TS) in response to your letter dated March 21, 2001, as supplemented June 28, 2001. Florida Power Corporation (FPC) submitted a request for changes to the CR-3 Improved Technical Specifications (ITS) to implement a reroll process to repair degraded steam generator tubes and allow the reroll repairs to be used in both the upper and lower tubesheets.
منابع مشابه
Estimate Submarine Groundwater Discharge to Crystal River/Kings Bay in Florida with the Help of a Hydrodynamic Model
Crystal River/Kings Bay is a spring-fed estuarine system located on the west coast of the Florida peninsula. During 2008-2009, a field investigation was conducted to measure submarine groundwater discharges (SGDs) from numerous spring vents in Kings Bay. Based on directly measured real-time SGD data, an empirical relationship that links SGD with tides in Kings Bay and the groundwater level meas...
متن کاملApplication of Bayesian Inversion Techniques on Multi Frequency Eddy Current Data for Sub Surface Crack Profiling In Steam Generator Tubing
Steam generator (SG) tubing in nuclear plant offers a barrier between the radioactive material and steam. Effective NDT of the SG tubing is mandatory to ensure the safe operation of nuclear power plants. Multi-frequency eddy current (EC) NDT is being exercised in the nuclear industry. Detection and subsequent crack profiling from the acquired EC signals is a challenging task once dealt with sub...
متن کاملAnalytical Determination of Critical Flaw Dimensions in Steam Generator Tubing
One of the actual problems of safe and reliable operation of NPP units with pressurized reactors is the development of tube plugging criterion for steam generator tubing. The basis for plugging criterion development is associated with existence of flaws with critical sizes at steam generator tubes. For effective application of this criterion the conditions of flaw instability should be analyzed...
متن کاملInstrument Surveillance and Calibration Verification Through Plant Wide Monitoring Using Autoassociative Neural Networks
The approach to instrument surveillance and calibration verification (ISCV) through plant wide monitoring proposed in this paper is an autoassociative neural network (AANN) which will utilize digitized data presently available in the Safety Parameter Display computer system from Florida Power Corporations Crystal River #3 nuclear power plant. An autoassociative neural network is one in which th...
متن کاملMULTICRITERION SYNTHESIS OF INTELLIGENT CONTROL SYSTEMS OF GENERATING UNIT OF NUCLEAR POWER STATION
The paper is devoted to solution of some problems in nuclear power station generating unit intellectual control systems using genetic algorithms on the basis of control system model development, optimizations methods of their direct quality indices and improved integral quadratic estimates. Some mathematical vector models were obtained for control system multicriterion quality indices with due ...
متن کامل