The X-ray Binary Population in M33: Ii. X-ray Spectra and Variability
نویسندگان
چکیده
In this paper we investigate the X-ray spectra and X-ray spectral variability of compact X-ray sources for 3 Chandra observations of the Local Group galaxy M33. The observations are centered on the nucleus and the star forming region NGC 604. In the observations 261 sources have been detected. For a total of 43 sources the number of net counts is above 100, sufficient for a more detailed spectral fitting. Of these sources, 25 have been observed in more than one observation, allowing the study of spectral variability on ∼months timescales. A quarter of the sources are found to be variable between observations. However, except for two foreground sources, no source is variable within any observation above the 99% confidence level. Only six sources show significant spectral variability between observations. A comparison of NH values with HI observations shows that X-ray absorption values are consistent with Galactic X-ray binaries and most sources in M33 are intrinsically absorbed. The pattern of variability and the spectral parameters of these sources are consistent with the M33 X-ray source population being dominated by X-ray binaries: Two thirds of the 43 bright sources have spectral and timing properties consistent with X-ray binaries; we also find two candidates for super-soft sources and two candidates for quasi-soft sources. Subject headings: X-rays: binaries — galaxies: Local Group — galaxies: individual (M33)
منابع مشابه
Precise Measurement of the Spin Parameter of the Stellar - Mass Black Hole M 33 X - 7
In prior work, Chandra and Gemini-North observations of the eclipsing X-ray binary M33 X-7 have yielded measurements of the mass of its black hole primary and the system’s orbital inclination angle of unprecedented accuracy. Likewise, the distance to the binary is known to a few percent. In an analysis based on these precise results, fifteen Chandra and XMM-Newton X-ray spectra, and our fully r...
متن کاملX-ray spectra calculation for different target-filter of mammograms using MCNP Code
ABSTRACTBackground: An electron beam generated X-ray spectrum consists of characteristic X-ray and continuous bermsstrahlung. The aim of this research is calculating and comparing X-ray spectra for different target filter of mammograms. Materials and Methods: Monte Carlo is a very powerful tool to simulate a series of different target-filter assembly in order to calculate the X-ray spectra. MC...
متن کاملUnfolding X-ray spectrum in the diagnostic range using the Monte Carlo Code MCNP5
Introduction: Unfolding X-ray spectrum is a powerful tool for quality control of X-ray tubes. Generally, the acquisition of the X-ray spectrum in diagnostic radiology departments is complicated and difficult due to high photon flux. Measurement of x ray spectra using radiation detectors could not be performed accurately, because of the pulse pile up. Therefore, indirect methods...
متن کاملForty Years of X-Ray Binaries
In 2012 it was forty years ago that the discovery of the first X-ray binary Centaurus X-3 became known. That same year it was discovered that apart from the High-Mass X-ray Binaries (HMXBs) there are also Low-Mass X-ray Binaries (LMXBs), and that Cygnus X-1 is most probably a black hole. By 1975 also the new class of Be/X-ray binaries was discovered. After this it took 28 years before ESAs INTE...
متن کاملBeppoSAX spectroscopy of the luminous X - ray sources in M 33
The nearby galaxy M33 was observed by the imaging X-ray instruments on-board BeppoSAX. Two observations at different phases of the 105.9 day intensity cycle of the luminous central source X-8 failed to reveal the expected modulation, suggesting that it is probably transitory. Similar behavior has been observed from several X-ray binary sources. This strengthens somewhat the idea that M33 X-8 is...
متن کامل