An automated scoring procedure for the micronucleus test by image analysis.
نویسندگان
چکیده
The micronucleus assay (MNT) in human lymphocytes is frequently used to assess chromosomal damage as a consequence of environmental mutagen exposure, to assess the effect of mutagens or to search for reduced DNA repair capacity after a mutagenic challenge. We have established an automated scoring procedure for the cytokinesis blocked MNT based on computerized image analysis (Metasystems Metafer 4 version 2.12). To evaluate the results we used the reproducibility of counts, established a dose-response curve for gamma-irradiation and used the ability of the system to differentiate between breast cancer patients and controls as a biological reference, a difference which we had observed before by visual counting. Blood cultures were irradiated with gamma-rays (2 Gy) at the beginning and treated with cytochalasin B during the last 24 h. The slides were stained with Giemsa for visual counting and with DAPI for automated analysis. Our test sample consisted of 73 persons (27 with breast cancer and 26 female and 20 male controls). A comparison between visual counting (controls, mean MN frequency 313) and automated counting (mean MN frequency 106) in slides from the same culture revealed a large drop for the automated counts. However, the automated counts were as reproducible as the visual counts [coefficient of variation (CV) on the sample approximately 20%; CV on repeated counts of the same slides approximately 5%] and both counts were highly correlated. Furthermore, the discrimination between cases and controls improved for automated counting of slides from the same cultures [visual odds rato (OR) < or = 4.0, P = 0.009; automated OR > 16, P < 0.0001], with a strong dependence on the set of parameters used. This improvement was confirmed in a validation sample of an additional 21 controls and 20 cases (OR = 11, P = 0.0018) performed as a prospective or diagnostic test.
منابع مشابه
I-1: Screening of Subfertile Men for Testicularlar Carcinoma In Situ by An Automated Image Analysis-Based Cytological Test of The Ejaculate
Background: Testicular cancer (TC) is usually diagnosed after manifestation of an overt tumour. Tumour formation is preceded by a pre-invasive and asymptomatic stage, carcinoma in situ (CIS) testis, except for very rare subtypes. The CIS cells are located within seminiferous tubules but can be exfoliated and detected in ejaculates with specific CIS markers. Materials and Methods: We have built ...
متن کاملAutomatic analysis of the micronucleus test in primary human lymphocytes using image analysis.
The in vitro micronucleus test (MNT) is a well-established test for early screening of new chemical entities in industrial toxicology. For assessing the clastogenic or aneugenic potential of a test compound, micronucleus induction in cells has been shown repeatedly to be a sensitive and a specific parameter. Various automated systems to replace the tedious and time-consuming visual slide analys...
متن کاملSemi-quantitative segmental perfusion scoring in myocardial perfusion SPECT: visual vs. automated analysis
Introduction: It is recommended that the physician apply at least a semi-quantitative segmental scoring system in myocardial perfusion SPECT. We aimed to assess the agreement between automated semi-quantitative analysis using QPS (quantitative Perfusion SPECT) software and visual approach for calculation of summed stress score (SSS), summed rest score (SRS) and summed difference score (SDS). ...
متن کاملThe micronucleus assay as a biological dosimeter of in vivo ionising radiation exposure.
Biological dosimetry, based on the analysis of micronuclei (MN) in the cytokinesis-block micronucleus (CBMN) assay can be used as an alternative method for scoring dicentric chromosomes in the field of radiation protection. Biological dosimetry or Biodosimetry, is mainly performed, in addition to physical dosimetry, with the aim of individual dose assessment. Many studies have shown that the nu...
متن کاملEvaluation of an automated in vitro micronucleus assay in CHO-K1 cells.
In this paper, we describe the evaluation of an automated in vitro micronucleus assay using CHO-K1 cells in 96-well plates. CHO-K1 cells were pre-loaded with a cell dye that stains the cytoplasm, after which the cells were treated with the test compounds for either 3h (for the +S9 condition) or 24h (for the -S9 condition). A total of 10 concentrations were tested, of which the top five concentr...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Mutagenesis
دوره 19 5 شماره
صفحات -
تاریخ انتشار 2004