Large volume spacer devices and the influence of high dose beclomethasone dipropionate on hypothalamo-pituitary-adrenal axis function.

نویسندگان

  • P H Brown
  • A P Greening
  • G K Crompton
چکیده

BACKGROUND The systemic effects of the inhaled corticosteroid beclomethasone dipropionate are reduced if the drug is inhaled through a large volume spacer. Use of spacers may therefore permit higher doses to be given without causing hypothalamo-pituitary-adrenal suppression. METHODS Randomised, double blind, double dummy, parallel group study was carried out in adults with chronic asthma to determine the dose of beclomethasone dipropionate causing hypothalamo-pituitary-adrenal suppression when the drug was administered by metered dose aerosol with and without a large volume spacer. After a four week run in taking 1.5 mg beclomethasone daily 50 patients underwent tests of hypothalamo-pituitary-adrenal function (measurement of 0900 h serum cortisol concentration and 24 hour urinary free cortisol excretion and the short tetracosactrin test). Six patients had hypothalamo-pituitary-adrenal suppression (results of at least two tests subnormal) and asthma was well controlled in six others. Thirty eight patients received increasing doses of beclomethasone with (group S) or without (group MDI) a 750 ml spacer. The daily dose was increased by 0.5 mg at monthly intervals until hypothalamo-pituitary-adrenal suppression developed or a dose of 5 mg/day was achieved. Asthma symptoms and peak expiratory flow were recorded daily. RESULTS Twenty three patients completed the study, one (group S) reaching a dose of 5 mg beclomethasone dipropionate daily without hypothalamo-pituitary-adrenal suppression. Reasons for withdrawal were poor compliance (n = 10), the patient's decision (n = 3), and asthma that was too unstable (n = 2). "Intention to treat" analysis showed that the median dose of beclomethasone causing hypothalamo-pituitary-adrenal suppression was similar in the two groups (3.25 mg in S v 3.0 mg in MDI; 95% confidence interval (CI) for difference -1.0 to 1.0 mg). At 2 mg/day of beclomethasone most patients in both groups had well controlled asthma and there were no differences in symptoms or peak flow between the groups. Good control at this dose did not permit conclusions to be drawn about the efficacy of higher doses. CONCLUSIONS There is wide interindividual variation in the dose of beclomethasone dipropionate causing hypothalamo-pituitary-adrenal suppression. Whether or not a spacer is used, doses higher than the currently accepted maximum of 2 mg/day can be taken by many adults with asthma without causing subnormal function of the hypothalamo-pituitary-adrenal axis. Whether these higher doses are more effective in controlling asthma remains to be established.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Systemic effects of high dose inhaled steroids: comparison of beclomethasone dipropionate and budesonide in healthy subjects.

BACKGROUND Systemic absorption of inhaled corticosteroids may adversely influence the function of the hypothalamo-pituitary-adrenal axis, bone metabolism, and circulating leucocytes. These changes can be used to assess the safety of different types and modes of administration of these drugs. METHODS The study was a randomised, double dummy, crossover design with nine healthy adults. It compar...

متن کامل

Adrenal function and high dose inhaled corticosteroids for asthma.

OBJECTIVE To investigate effects on adrenal function of fluticasone, a recently released inhaled steroid preparation with lower systemic bioavailability than beclomethasone dipropionate. METHODS 34 children on high doses (400-909 micrograms/m2/d) of inhaled beclomethasone dipropionate or budesonide were recruited into a double blind, crossover study investigating the effects on adrenal functi...

متن کامل

Systemic activity of inhaled and swallowed beclomethasone dipropionate and the effect of different inhaler devices.

Inhaled glucocorticoids such as beclomethasone dipropionate, which are used in the treatment of asthma, may be associated with systemic adverse effects. To determine whether any systemic absorption following the inhalation of beclomethasone was a result of drug being absorbed from the lung (inhaled fraction) or the gastrointestinal tract (swallowed fraction), we studied normal subjects after th...

متن کامل

Systemic effects of inhaled corticosteroids on growth and bone turnover in childhood asthma: a comparison of fluticasone with beclomethasone.

Inhaled steroids are frequently used in childhood asthma, but concerns based on limited objective evidence remain, regarding long-term side-effects. In this study the systemic effects of standard doses of inhaled steroids in childhood asthma were assessed, comparing beclomethasone dipropionate (BDP) with fluticasone propionate (FP). The study was prospective, randomized and double-blind. Twenty...

متن کامل

High-dose inhaled steroids in asthmatics: moderate efficacy gain and suppression of the hypothalamic-pituitary-adrenal (HPA) axis. Research Council of the Norwegian Thoracic Society.

We wanted to evaluate the improvement in efficacy when increasing the daily dose of inhaled steroids and to compare the efficacy, safety, and tolerance of 1.6 mg beclomethasone dipropionate (BDP) with that of 2.0 mg fluticasone propionate (FP). The study was a randomized, double-blind, 3 month, multicentre study. One hundred and thirty four asthmatics currently using inhaled steroids (0.4-1.6 m...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Thorax

دوره 48 3  شماره 

صفحات  -

تاریخ انتشار 1993