7T vs. 4T: RF power, homogeneity, and signal-to-noise comparison in head images.

نویسندگان

  • J T Vaughan
  • M Garwood
  • C M Collins
  • W Liu
  • L DelaBarre
  • G Adriany
  • P Andersen
  • H Merkle
  • R Goebel
  • M B Smith
  • K Ugurbil
چکیده

Signal-to-noise ratio (SNR), RF field (B(1)), and RF power requirement for human head imaging were examined at 7T and 4T magnetic field strengths. The variation in B(1) magnitude was nearly twofold higher at 7T than at 4T ( approximately 42% compared to approximately 23%). The power required for a 90 degrees pulse in the center of the head at 7T was approximately twice that at 4T. The SNR averaged over the brain was at least 1.6 times higher at 7T compared to 4T. These experimental results were consistent with calculations performed using a human head model and Maxwell's equations. Magn Reson Med 46:24-30, 2001.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of the Characteristics of MRI Coils in Terms of RF Non-Homogeneity Using Routine Spin Echo Sequences

Introduction: One of the major causes of image non-uniformity in MRI is due to the existence of  non-homogeneity in RF receive and transmit. This can be the most effective source of error in  quantitative  studies  in  MRI  imaging.  Part  of  this  non-homogeneity  demonstrates  the  characteristics of RF coil and part of it is due to the interaction of RF field with the material being  imaged...

متن کامل

In vivo 1H NMR spectroscopy of the human brain at high magnetic fields: metabolite quantification at 4T vs. 7T.

A comprehensive comparative study of metabolite quantification from the human brain was performed on the same 10 subjects at 4T and 7T using MR scanners with identical consoles, the same type of RF coils, and identical pulse sequences and data analysis. Signal-to-noise ratio (SNR) was increased by a factor of 2 at 7T relative to 4T in a volume of interest selected in the occipital cortex using ...

متن کامل

B 1 shimming with a standard 2 channel headcoil at 7 T : possibilities & limitations

Purpose: To study the possibilities and limitations of RF phase and amplitude shimming with a standard 2 channel head coil at 7T. Introduction One of the main problems in high field MRI is the reduced SNR and loss in contrast due to inhomogeneous B1 RF transmit fields. Spatial homogeneity is of primary importance for diagnostic imaging. At 3T the homogeneity problem is mainly limited to regions...

متن کامل

Gain of Imaging Fidelity by Employing a Higher Number of Independent Transmit Channels Together with Slice-Selective Radio-Frequency (RF) Shimming at 7T

Dielectric resonance effects and radio-frequency (RF) power deposition have become challenging issues for magnetic resonance imaging at ultrahigh-field (UHF) strengths. The use of transmit (Tx) coil arrays with independently-driven RF sources using a parallel transmission system is a promising method for alleviating the resulting RF inhomogeneities. In this study, the effect on homogeneity and ...

متن کامل

Traveling Wave Imaging of the Human Head at 7 Tesla: Assessment of SNR, Homogeneity and B1+ Efficiency

Introduction: The traveling wave concept for 7T MR imaging was first demonstrated by Brunner et al [1]. In the most common RF transmit coil designs, a quadrature RF field is created within a cylindrical volume in the near-field regime. In contrast, the traveling wave approach creates a traveling wave mode down the entire bore of the scanner. This has the potential to provide more uniform excita...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 46 1  شماره 

صفحات  -

تاریخ انتشار 2001