Penetration of the subarachnoid space by fetal scalp electrode.

نویسندگان

  • D S Sharp
  • J M Couriel
چکیده

Penetration of the subarachnoid space by fetal scalp electrode Fetal scalp electrodes of various designs are used widely for continuous intrapartum fetal heart rate monitoring. Minor lacerations of the scalp are common, and 1-0-4-5% of infants may develop scalp ulceration or abscess.1 2 We describe two cases in which there was penetration of the subarachnoid space with leakage of cerebrospinal fluid associated with the use of a scalp electrode of the single helix type. Case reports Case 1-A 20 year old primigravida was admitted in spontaneous labour at 38 weeks of gestation. A fetal scalp electrode was applied at 4 cm cervical dilatation with the fetal head in the left occipitoanterior position. Spontaneous vaginal delivery of a mature boy weighing 3130 g occurred four hours later. The baby was in good condition with Apgar scores of 9 and 10 at one and five minutes respectively. Three hours after delivery we noted leakage of clear cerebrospinal fluid from the scalp electrode site over the posterior fontanelle. Conservative treatment with a dry dressing, prophylac-tic antibiotics, and nursing of the baby in a sitting position resulted in resolution of the leak within 48 hours without any apparent complications. Case 2-A 20 year old primigravida was admitted in spontaneous labour at 39 weeks. A fetal scalp electrode was applied at 3 cm cervical dilatation with the fetal head in the right occipitoanterior position. Spontaneous vaginal delivery of a mature girl weighing 3050 g occurred seven hours later. The baby was in good condition with Apgar scores of 9 and 10 at one and five minutes. Routine examination after birth disclosed leakage of clear fluid from the electrode site over the right parietal bone, 2-5 cm behind the posterior edge of the anterior fontanelle. As in case 1 there was rapid resolution of the leak (in this case within 24 hours) without any neurological complications.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Monitoring Fetal Heart Rate during Labor: A Comparison of Three Methods

The purpose of the study was to compare the accuracy of a noninvasive fetal heart rate monitor with that of ultrasound, using a fetal scalp electrode as the gold standard, in laboring women of varying body habitus, throughout labor and delivery. Laboring women requiring fetal scalp electrode were monitored simultaneously with the investigational device (noninvasive fetal ECG), ultrasound, and f...

متن کامل

Comment on the article "accuracy and reliability of fetal heart rate monitoring using maternal abdominal surface electrodes".

OBJECTIVE Compare the accuracy and reliability of fetal heart rate identification from maternal abdominal fetal electrocardiogram signals (ECG) and Doppler ultrasound with a fetal scalp electrode. DESIGN Prospective open method equivalence study. SETTING Three urban teaching hospitals in the Northeast United States. SAMPLE 75 women with normal pregnancies in labor at >37 weeks of gestatio...

متن کامل

Fetal-neonatal status following caesarean section for fetal distress.

Fetal biochemical and neonatal clinical data were compiled in 126 emergency Caesarean sections performed for fetal distress. The choice of anaesthetic technique was determined by the wishes of the mother. General anaesthesia was administered to 71 parturients and regional analgesia to 55 (subarachnoid block 33, extension of extradural block 22). The aetiologies of fetal distress and the skin in...

متن کامل

Evaluation of the fetal QT interval using non-invasive fetal ECG technology.

Non-invasive fetal electrocardiography (NI-FECG) is a promising alternative continuous fetal monitoring method that has the potential to allow morphological analysis of the FECG. However, there are a number of challenges associated with the evaluation of morphological parameters from the NI-FECG, including low signal to noise ratio of the NI-FECG and methodological challenges for getting refere...

متن کامل

The fetal electrocardiogram: current clinical developments in Nottingham.

The fetal electrocardiogram (FECG) has been recorded from 155 women in labor using a fetal scalp electrode and a minicomputerized enhanced averaging technique. Fetal hypoxia, acidosis, and stress have been diagnosed by analysis of blood from the fetal scalp, and post delivery from full gas analysis from blood taken from the umbilical artery and vein. Umbilical venous levels of serum lactate, ad...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British medical journal

دوره 291 6503  شماره 

صفحات  -

تاریخ انتشار 1985