A Levering Technique Using Small Parallel Rods for Open Reduction of High-Grade Thoracolumbar Dislocation
نویسندگان
چکیده
STUDY DESIGN Technical report. OBJECTIVE Dorsolumbar vertebral dislocations, with or without associated fractures, occur secondary to very high velocity trauma. The reduction procedures and techniques, which may be adopted in these situations, have been multifariously discussed in the literature. Our objective was to assess the outcome of a novel reduction maneuver, using parallel rods which we have employed in reduction of high-grade thoracolumbar fractures to achieve precise sagittal balance as well as accurate vertebral alignment with minimal soft tissue damage. METHODS The study included a total of 11 cases of thoracolumbar dislocations, who had presented to our emergency spine services following high-velocity trauma. After appropriate systemic stabilization and necessary investigations, all patients were surgically treated using the described technique. RESULTS There were no surgical complications at 2-year follow-up. Radiographs showed good reduction and maintained sagittal balance. CONCLUSION We believe that this technique is an excellent means of achieving safer, easier, and accurate reduction for restoration of sagittal/coronal balance and alignment in high-grade thoracolumbar dislocations. It is easily reproducible and predictable.
منابع مشابه
A Novel Reduction Manoeuver for Highly Unstable Thoraco- Lumbar Fracture Dislocation: Technical Note
Fracture dislocations of thoracic and lumbar vertebrae are commonly encountered and are a result of high velocity trauma (Fig 1) [1] . Surgical treatment poses challenge in terms of safe and effective reduction maneuvers. Various techniques have been diversely described in literature for reducing highly unstable thoracolumbar fractures. We describe a novel reduction maneuver which is slow, stea...
متن کاملOptimization of an ultra-high-resolution rectangular pixelated parallel-hole collimator with a CZT pixelated semiconductor detector for HiRe-SPECT system
Introduction: In nuclear medicine, the use of a pixelated semiconductor detector such as CZT is an of growing interest for introducing new devices. Especially, the spatial resolution can be improved by using a pixelated parallel-hole collimator with equal holes and pixel sizes based on the pixelated detector. The purpose of this study was to compare the effect of pixelated and ...
متن کاملComplete fracture-dislocation of the thoracolumbar spine without neurological deficit
RATIONALE Traumatic fracture of the thoracolumbar junction (T10-L2) is the most common fracture of the spinal column. Due to the disruption of the entire vertebrae column, the fracture-dislocation of the thoracolumbar spine is almost invariably associated with neurological injury. A complete fracture-dislocation of the thoracolumbar spine without neurological deficit is a rare entity. PATIENT...
متن کاملSimultaneous of Mid Third Clavicle Fracture and Type 3 Acromioclavicular Joint Dislocation; A Case Report
Simultaneous mid third clavicle fracture and acromioclavicular joint dislocation is a rare combination injury, as a result of high-energy trauma. We report a patient with a middle third clavicle fracture and ipsilateral grade three-acromioclavicular joint dislocation, which is a rare combination. The patient wanted to get back to work as soon as possible, so the fracture was fixed with recons...
متن کاملThoracolumbar junction injuries and their management with pedicle screws.
BACKGROUND To evaluate the use of pedicle screw fixation in earthquake injured thoracolumbar spine. METHODS Nineteen patients with posttraumatic instability of lower thoracic or upper lumbar spine were included in the study. White and Panjabi criteria was used to assess spinal instability. All patients underwent open reduction and internal fixation by posterior approach. Pedicles were localiz...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 7 شماره
صفحات -
تاریخ انتشار 2017