Venous pressure opposing aqueous outflow in patients with and without chronic open-angle glaucoma. Calculation from data obtained by indentation tonography and suction cup analysis using an electrical model of the eye.
نویسندگان
چکیده
Three groups of patients (those with chronic open-angle glaucoma, glaucoma suspects, and normals) were subjected to both tonography and suction cup analysis. The data, analyzed by an electrical model of the eye, showed that (1) venous pressure opposing aqueous outflow is higher in patients with chronic open-angle glaucoma and in glaucoma suspects than in normal patients; and (2) lack of pressure rise during the time that a perilimbal suction cup is applied to the eye may not be the restdt of faulty technique, as has been previously assumed, but may indicate inflow less than the stress relaxation of the ocular coats. The residts confirm that (1) patients with chronic open-angle glaucoma have a decreased facility of outflow, independent of other parameters; and (2) patients on both acetazolamide and epinephrine therapy have a decreased aqueous production.
منابع مشابه
An electrical model of the human eye. 3. The model and the eye during suction cup procedure, and its reconciliation with tonography.
The basic electrical model of the human eye can be distorted analogously to the distortion occasioned by the suction cup procedure. By using the values for the facility of outflow (C) and for stress relaxation (RQ) determined by tonography, the output of the model matches the clinically observed data when suitable adjustments are made for flow (F) and episcleral venous pressure (Pv). From such ...
متن کاملComparison of perilimbal suction cup analysis and tonography in the diagnosis of glaucoma.
IN the past few years there has been increasing interest in the use of the pressure cup technique for the investigation of aqueous humour dynamics. Rosengren (1956) demonstrated a rise of intra-ocular pressure when a positive pressure was applied to the sclera overlying Schlemm's canal. He suggested that this rise of pressure was due to continued formation and accumulation of aqueous humour, th...
متن کاملComparative aqueous outflow facility measurements by pneumatonography and Schiotz tonography.
Tonography was performed on 36 eyes of 15 normal and 3 primary open angle glaucoma patients using pneumatonography and classical Schiotz tonography. The average values of the coefficient of outflow facility (C) for the whole sample were virtually identical with both methods. However, both intersubject and interobserver variability were significantly higher with penumatonography. Although both m...
متن کاملAqueous Flow Measurements in Man by the Perilimbal Suction Cup Technique. Ii. Comparisons in Chronic Simple Glaucoma before and after Pilocarpine.
WITH the observation by Laqueur (1876) that tension of glaucomatous eyes could be reduced with physostigmine, and the corroboration of Weber (1877) that the same effect attended the use of pilocarpine, both substances have found a permanent place in therapy. Their precise action, however, remains obscure (Sugar, 1957; Becker and Shaffer, 1961). Unlike carbonic anhydrase inhibitors, such as acet...
متن کاملSome observations on chronic closed-angle glaucoma.
AT WHAT stage in its course closed-angle glaucoma may be said to have become chronic is difficult to define. When, however, pathological cupping of the optic disc and visual field loss have occurred in an eye with closedangle glaucoma, the disease may reasonably be said to have reached the chronic stage. The aqueous outflow in such an eye is usually regarded as being permanently impaired by the...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Investigative ophthalmology
دوره 5 6 شماره
صفحات -
تاریخ انتشار 1966