Measure and compare the Degree of Root Canal Transportation and Canal-centering ability of Twisted, ProTaper, and Conventional Stainless Steel K Files using Spiral Computed Tomography: An in vitro Study.

نویسندگان

  • F Rejula
  • R Christalin
  • Waseem Ahmed
  • Shiji Dinakaran
  • Anupama S Gopinathan
  • Anulekh Babu
چکیده

AIM The aim of this study was to compare canal transportation and centering ability of Twisted files (TF) and ProTaper (PT) files with conventional stainless steel (SS) K files. MATERIALS AND METHODS Thirty mandibular premolar teeth with root curvature of 25 to 35° were selected. The samples were randomly divided into three groups of 10 each according to the type of files used for instrumentation. Group I was instrumented using TF, group II with PT files according to the manufacturer's recommendations, and group III with samples prepared with pre-curved SS K files using a step-back technique. After preparation, the samples were assessed using spiral computed tomography. Three sections were recorded at coronal, middle, and apical levels. Amount of transportation was assessed comparing with preinstrumentation images. Centering ability was calculated using Gambill's formula. The three groups were statistically compared using Student's t-test. RESULTS Twisted files showed the least canal transportation and the best centering ability followed by PT file system. Stainless steel K files showed the highest transportation and least centering ability. CONCLUSION Twisted files showed the least amount of transportation and better centering compared with the other file systems. CLINICAL SIGNIFICANCE The study gives information of TF, a recently introduced rotary system (2008) with regard to its efficacy in preparing curved root canals. This study has shown that the centering ratio of rotary nickel titanium was better than that of SS files.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An in-vitro Evaluation of canal transportation and centering ability of two rotary Nickel Titanium systems (Twisted Files and Hyflex files) with conventional stainless Steel hand K-flexofiles by using Spiral Computed Tomography.

BACKGROUND The purpose of this in-vitro study was to compare canal transportation and centering ability of Twisted and Hyflex Rotary Files with stainless steel hand k-flexofiles by using Spiral Computed Tomography. MATERIALS & METHODS A total of 90 freshly extracted human mandibular single rooted Premolar teeth were selected. The crowns were flattened with steel disks and a final dimension of...

متن کامل

Effects of preparation techniques on root canal shaping assessed by micro-computed tomography

BACKGROUND Root canal shaping without any procedural error is of the utmost preference. Therefore, the purpose of this study was to use micro-computed tomography to evaluate and compare the root canal shaping efficacy of ProTaper rotary files and standard stainless steel K-files. MATERIAL AND METHODS Sixty extracted upper second premolars were selected and were divided into 2 groups of 30. Be...

متن کامل

Evaluation of Canal Transportation and Centering Ability of Safesider and K-Flexofile: Using Cone-beam Computed Tomography

Abstract Background and aim: Maintaining the original geometry of canal is an important parameter in successful root canal treatment. The aim of this original study was evaluation of apical root canal transportation and centering ability of SafeSider and K-Flexofile using cone beam computed tomography. Materials and Methods: Mesiobuccal root canals of maxillary first molars, with 20-40° curvatu...

متن کامل

Comparison of Canal Transportation and Centering Ability of Wave One and SafeSider in Curved Root Canals Using Cone-Beam Computed Tomography

Background and Aim: Maintaining the original central canal path during cleaning and shaping of the root canal system plays an important role in the success of endodontic treatment. This study sought to compare canal transportation and centering ability of WaveOne and SafeSider rotary files using cone-beam computed tomography (CBCT). Materials and Methods: This in-vitro, experimental study was ...

متن کامل

Comparison of transportation and centering ability using RECIPROC and iRace: A cone-beam computed tomography study

BACKGROUND AND AIM: Root canal treatment, especially in curved and constricted root canals, can be very difficult and time consuming. Several investigations have compared the reciprocating and full sequence motions in terms of shaping ability. The purpose of the present study was to compare the root canal transportation and centering ability of RECIPROC and iRace using cone-beam computed tomogr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The journal of contemporary dental practice

دوره 18 6  شماره 

صفحات  -

تاریخ انتشار 2017