An Electromagnetic Calorimeter Based on Liquid Krypton with Tower Read-Out Structure

نویسنده

  • Sandro Palestini
چکیده

II. EXPERIMENTAL REQUIREMENTS ON CALORIMETER Decays of K mesons into ππ are reconstructed imposing that the four photons detected by the calorimeter have invariant mass equal to the kaon mass, checking that the kaon candidate parent is collinear with the beam direction, and that gamma pairs can be reconstructed as originating from π decays. The main detector requirements can be classified as follows.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

EUROPEAN ORGANIZATION FOR NUCLEAR RESEARCH CERN{PPE/95{64 21 April 1995 Performance of an Electromagnetic Liquid Krypton Calorimeter based on a Ribbon Electrode Tower Structure

The NA48 collaboration is preparing a new experiment at CERN aiming to study CP violation in the K K0 system with an accuracy of 2 10 4 in the parameter Re( = ). Decays into two 's will be recorded by a quasi-homogeneous liquid krypton calorimeter. A liquid krypton calorimeter has been chosen to combine good energy, position and time resolution with precise charge calibration and long-term stab...

متن کامل

The liquid krypton calorimeter for experiment CERN-NA48

A quasi-homogeneous liquid krypton electromagnetic calorimeter is under construction for a precision study of CP violation in neutral kaons decays. The main characteristics of the detector are discussed, together with results on energy, space and time resolution obtained with a prototype detector.

متن کامل

Natrium : Use of FPGA embedded processors for real - time data compression

We present test results and characterization of a data compression system for the readout of the NA62 liquid krypton calorimeter trigger processor. The Level-0 electromagnetic calorimeter trigger processor of the NA62 experiment at CERN receives digitized data from the calorimeter main readout board. These data are stored on an on-board DDR2 RAM memory and read out upon reception of a Level-0 a...

متن کامل

The NA48 LKr calorimeter digitizer electronics chain

The 13 500 channels of the NA48 liquid-krypton electromagnetic calorimeter readout electronics were put into operation in 1997. The digitizer electronics employs a new gain switching technique that expands the dynamic range of a standard 10-bit ADC to 14 bits at 40MHz sampling rate employing a custom-developed integrated circuit (KRYPTON). The KRYPTON has been fabricated in 1.2lm BiCMOS technol...

متن کامل

Recent NA48 results on rare K decays

The NA48 experiment has been designed for a precise measurement of the CP-violation parameter Re( ′/ ). It makes use of simultaneous KL and KS beams produced at two different targets, situated 120m from each other. The main two elements of the setup are charged particle magnetic spectrometer and liquid krypton electromagnetic calorimeter (LKr). The spectrometer consists of a dipole magnet with ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2007