Patterns of shortening and thickening of the human diaphragm.

نویسندگان

  • J L Wait
  • R L Johnson
چکیده

To study how the human diaphragm changes configuration during inspiration, we simultaneously measured diaphragm thickening using ultrasound and inspired volumes using a pneumotachograph. Diaphragm length was assessed by chest radiography. We found that thickening and shortening were greatest during a breath taken primarily with the abdomen. However, the degree of thickening was greater than expected for fiber shortening, assuming parallel muscle fibers and no shear. So, to clarify this unexpected finding, we considered geometric models of the diaphragm. How a muscle thickens as its fibers shorten is critically dependent on geometry. Thus, if a flat rectangular sheet of muscle shortens along one dimension, surface area-to-length ratio along this dimension should remain constant, and thickness would be inversely proportional to length during shortening. The simplest model of the diaphragm, however, is a cylindrical sheet of muscle in the zone of apposition capped by a dome; the ratio of surface area to radial fiber length in the dome is substantially less than the ratio of area to length of the cylindrical zone of apposition; hence, as the zone of apposition shortens while the dome radius remains constant, the ratio of total surface area to combined length (i.e., dome + zone of apposition) must decrease and thickening of the muscle correspondingly must increase more than expected for a simple rectangular strip. A similar relationship can be derived between thickening and length in a muscle sheet with a wedge-shaped insertion into a thin flat tendon. Comparison of calculations with these types of models to data from human subjects indicates that the unexpected thickening in the zone of apposition is explained by the peculiar geometry of the diaphragm. The greater thickening of the diaphragm in the zone of apposition suggests that more of the muscle mass and more sarcomeres are retained in the zone of apposition as the dome descends. Physiologically, this greater thickening may have importance by reducing wall stress in the zone of apposition and reducing the work or energy requirements per sarcomere.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Diaphragm thickening during inspiration.

Ultrasound has been used to measure diaphragm thickness (Tdi) in the area where the diaphragm abuts the rib cage (zone of apposition). However, the degree of diaphragm thickening during inspiration reported as obtained by one-dimensional M-mode ultrasound was greater than that predicted by using other radiographic techniques. Because two-dimensional (2-D) ultrasound provides greater anatomic de...

متن کامل

Lipedematous Scalp: A Case Report

Lipedematous scalp (LS) and Lipedematous Alopecia (LA) are uncommon disorders of unknown etiology, pathogenesis and treatment. They are characterized by thickening of the subcutaneous layer of the scalp and a boggy scalp on palpation. Also, hair loss or shortening of hair is seen in LA. In this report, we describe LS in a 42-year-old woman presented with a diffuse thickened and spongy scalp. To...

متن کامل

Patterns of inspiratory muscle shortening during hypoxia and hypercapnia in dogs.

The shortening of parasternal intercostal muscles (Para) and crural (Cru) and costal diaphragms (Cos) are not precisely understood. We therefore examined shortening patterns of these inspiratory muscles by using chronically implanted sonomicrometers in dogs. To avoid acute effects of surgery, measurements were performed 3 weeks after implanting the sonomicrometers. Patterns of length changes of...

متن کامل

Postsystolic shortening of acutely ischemic canine myocardium predicts early and late recovery of function after coronary artery reperfusion.

Postsystolic shortening and thickening of ischemic and postischemic myocardium are well-recognized phenomena, but their significance is controversial. To discover whether postsystolic shortening and thickening might represent an active process and to establish their place as possible predictors of functional recovery during and after recovery from ischemia, we examined correlations in severely ...

متن کامل

Canine Myocardium Predicts Early and Late Recovery of Function After Coronary Artery Reperfusion

Postsystolic shortening and thickening of ischemic and postischemic myocardium are wellrecognized phenomena, but their significance is controversial. To discover whether postsystolic shortening and thickening might represent an active process and to establish their place as possible predictors of functional recovery during and after recovery from ischemia, we examined correlations in severely i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of applied physiology

دوره 83 4  شماره 

صفحات  -

تاریخ انتشار 1997