Arthroscopic transosseous rotator cuff repair: technical note, outcomes, and complications.

نویسندگان

  • Eric M Black
  • Albert Lin
  • Uma Srikumaran
  • Nitin Jain
  • Michael T Freehill
چکیده

The goal of this study was to review the authors' initial experience with arthroscopic transosseous rotator cuff repair. Thirty-one patients with full-thickness rotator cuff tears underwent arthroscopic transosseous rotator cuff repair over a 15-month period. Preoperatively, demographics and subjective scores were recorded. Postoperatively, pain levels, subjective shoulder values, satisfaction scores, American Shoulder and Elbow Surgeons (ASES) scores, complications, and reoperations were noted with a minimum 2-year follow-up. The relationships between pre- and intraoperative variables and outcome scores were determined with univariate analysis. Average patient age was 56 years, and 23 patients (74%) were men. Twenty patients (65%) underwent primary rotator cuff repair, and 11 patients (35%) underwent revision repair. Average time to follow-up was 26 months. Average preoperative pain level and subjective shoulder value were 5.1 of 10 and 35%, respectively. Average postoperative scores included pain level of 0.9 of 10, subjective shoulder value of 84%, satisfaction score of 90.6 of 100, and ASES score of 86.3 of 100. There were 3 (9.7%) major and 2 (6%) minor complications. Patients undergoing revision rotator cuff repair had significantly worse outcomes (pain level, subjective shoulder value, ASES score; P<.05) compared with those undergoing primary repair, and cortical augmentation did not significantly affect outcome. Overall, outcomes after arthroscopic transosseous rotator cuff repair are good, although patients undergoing revision repair do not have the same outcomes as those undergoing primary cuff repair. The procedure is not without complications (9.7% major, 6% minor complications). Cortical augmentation may be used to supplement fixation, although it does not necessarily affect outcomes. Patients without such augmentation may be at increased risk for suture cutout through the bone.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Clinical outcomes of single versus double row, transosseous equivalent arthroscopic rotator cuff repair

Rotator cuff tears are common and are expected to present with increasing frequency as the population ages. Various techniques in surgical repair have been described to improve clinical outcomes. A arthroscopic transosseous-equivalent double row repair is believed to be superior, with improved tendon to bone contact area and reduced gap formation. In our series of 143 patients, with 76 undergoi...

متن کامل

Arthroscopic bone tunnel augmentation for rotator cuff repair.

Transosseous repair of the rotator cuff has been shown to recreate the anatomic rotator cuff footprint in a secure and cost-efficient manner. However, the potential for sutures cutting through bone remains a concern with this strategy. Devices have been used successfully during open transosseous rotator cuff repair to augment the bone tunnels, potentially avoiding suture cut-out through the wea...

متن کامل

An Arthroscopic Knotless Technique for Anatomical Restoration of the Rotator Cuff and Superior Capsule: The Double-Layer Cinch Bridge

Rotator cuff repairs are the most common procedures in shoulder surgery, but still show long-term retear rates of up to 70%. Nonanatomic reconstruction is one possible cause of repair failure. The rotator cuff histologically consists of 5 separate layers of which 2 are macroscopically identifiable: the superior or tendinous layer and the inferior or capsule-ligamentous layer. In case of rotator...

متن کامل

Arthroscopic Transosseous Rotator Cuff Repair

BACKGROUND Mechanical factors are at the basis of any tendon healing process, being pressure an aspect able to positively influence it. For this reason transosseous rotator cuff repair represents the gold standard procedure for patients affected by a cuff tear, maximizing the tendon footprint contact area and reducing motion at the tendon to bone interface. METHODS The Authors present an all ...

متن کامل

Outcomes following arthroscopic transosseous equivalent suture bridge double row rotator cuff repair: a prospective study and short-term results

BACKGROUND The transosseous-equivalent cross bridge double row (TESBDR) rotator cuff (RC) repair technique has been developed to optimize healing biology at a repaired RC tendon insertion. It has been shown in the laboratory to improve pressurized contact area and mean foot print pressure when compared with a double row anchor technique. Pressure has been shown to influence healing between tend...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Orthopedics

دوره 38 5  شماره 

صفحات  -

تاریخ انتشار 2015