Dihydroxyvitamin D 3 in Serum : Sample Purification with Sep - Pak C - i 8 Cartridges and Liquid Chromatography before Protein - Binding Assay
نویسنده
چکیده
We describe a precise, specific method for measunng 24,25dihydroxyvitamin D3 in human serum. A 2-mL serum sample is extracted with acetonitrile and passed through a Sep-Pak C-18 cartridge. The sample is further purified by “highperformance’ liquid chromatography under isocratic conditions on a normal-phase column (Radial-Pak silica-gel cartridge), then subjected to a protein-binding assay. The mean concentration of 24,25-dihydroxyvitamin D3 in serum from 22 normal adults (measured during the spring) was 2.9 tg/L (SD 1.9, range 6.3-0.42 g/L). The intra-assay CV was 7.7%, the interassay CV 11.2%. Purification of the sample with SepPak C-i 8 and liquid chromatography on normal plus reversed-phase columns leads to a mean value of 3.4 /.Lg/L(SD 1.6 g/L, n = 12), not significantly different from results with our method.
منابع مشابه
Specific estimation of 24,25-dihydroxyvitamin D in plasma by gas chromatography-mass spectrometry.
This paper describes a specific mass-fragmentographic method, involving a stable-isotope-labeled internal standard, for measurement of 24,25-dihydroxyvitamin D in human plasma. Vitamin D metabolites were rapidly extracted from plasma by using Sep-Pak C18 cartridges and separated into fractions on Sep-Pak SIL cartridges. The polar fraction, containing the dihydroxylated metabolites, was further ...
متن کاملDeveloped Method Application for Nitrite Ion (NO2¯ ) Analysis of Tib -186 Macrophage Like Cell Lines by Rapid Isocratic HPLC System with High Sensitive Glassy Carbon Electrochemical Detector
A rapid isocratic method of high performance liquid chromatography system (HPLC) with a glassy carbon working electrode of electrochemical detector is set up for quantitative detection of trace amount of nitrite ion (NO2¯) in aqueous protein containing cell lysate, cell media, plasma, serum, urine and other body fluids. The solid extraction reversed phase cartridges ...
متن کاملImproved method for quantifying vitamin D in proprietary infants' formulas and in breast milk.
In this new method for quantifying vitamin D in infants' formulas and breast milk, after repeated lipid extraction, samples are further purified by passage through Sep-Pak cartridges, followed by liquid chromatography, then quantified by competitive protein-binding assay. Analytical recovery is estimated by use of added 3H-labeled vitamin D. For repeated assays of a reconstituted proprietary po...
متن کاملImprovements in the simultaneous determination of calcidiol and calcitriol in human serum or plasma.
Technical improvements have been applied to reduce the time required for the determination of calcidiol and calcitriol in serum or plasma. The modifications include the use of Sep-Pak C18 cartridges for the extraction of calciol metabolites from serum instead of a classical liquid/liquid extraction, a considerable shortening of the HPLC purification time compared with our previously described m...
متن کاملFacile and rapid one-step radiosynthesis of [(18)F]BAY94-9172 with a new precursor.
INTRODUCTION [(18)F]BAY94-9172 (Florbetaben) (Compound 8) is a positron emission tomography (PET) tracer that is currently in Phase III study for in vivo mapping of fibrillar amyloid β as a pathological hallmark for Alzheimer's disease. This work reports new methods for the synthesis of [(19)F]BAY94-9172 and its two different precursors and radiosynthesis of [(18)F]BAY94-9172 with the two precu...
متن کامل