Neural network-based calibration of positron emission tomograph detector modules

نویسندگان

  • Beatrice Lazzerini
  • Francesco Marcelloni
  • Giovanni Marola
  • Simone Galigani
چکیده

In this paper we describe a neural network-based method aimed at automatically calibrating the detector module contained in a scanner for a highresolution positron emission tomography (PET) system for small animals. The detector module is composed of crystal elements, arranged in a regular matrix and sensitive to gamma rays emitted by a radioactive source. The crystal matrix is optically coupled to a position-sensitive photo-multiplier tube, which reconstructs the original image. Calibration, required to cope with spatial distortions introduced by the optical system, consists of a segmentation process of the image produced after the photo-multiplier tube into a fixed number of areas. The purpose of this segmentation is to map each pixel of the perceived image onto the pertinent crystal, which was actually struck by the gamma ray emitted by the radioactive source.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design and Engineering Aspects of a High Resolution Positron Tomograph for Small Animal Imaging*

We describe the Sherbrooke positron emission tomograph, a very high resolution device dedicated to dynamic imaging of small laboratory animals. Its distinctive features are: small discrete scintillation detectors based on avalanche photodiodes (APD) to achieve uniform, isotropic, very high spatial resolution; parallel processing for low deadtime and high count rate capability; multispectral dat...

متن کامل

Development of an in-cylinder processes model of a CVVT gasoline engine using artificial neural network

Today, employing model based design approach in powertrain development is being paid more attention. Precise, meanwhile fast to run models are required for applying model based techniques in powertrain control design and engine calibration. In this paper, an in-cylinder process model of a CVVT gasoline engine is developed to be employed in extended mean valve control oriented model and also mod...

متن کامل

Positron Emission Tomography ( PET )

The principle of image formation in tomography is summarised. The principle ofpositron electron annihilation is introduced. The principle of coincidence techniques is illustrated. Detector development and perspectives for positron emission tomography (PET) instrumentation for medical research is presented. The physical processes in in positron annihilation, photon scattering and tomograph desig...

متن کامل

A retrospective on the LBNL PEM project.

We present a retrospective on the LBNL Positron Emission Mammography (PEM) project, looking back on our design and experiences. The LBNL PEM camera utilizes detector modules that are capable of measuring depth of interaction (DOI) and places them into 4 detector banks in a rectangular geometry. In order to build this camera, we had to develop the DOI detector module, LSO etching, Lumirror-epoxy...

متن کامل

A Method for Pre-Calibration of DI Diesel Engine Emissions and Performance Using Neural Network and Multi-Objective Genetic Algorithm

Diesel engine emission standards are being more stringent as it gains more publicity in industry and transportation. Hence, designers have to suggest new controlling strategies which result in small amounts of emissions and a reasonable fuel economy. To achieve such a target, multi-objective optimization methodology is a good approach inasmuch as several types of ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2004