Characterization and optimization of microelectrode arrays for in vivo nerve signal recording and stimulation.
نویسندگان
چکیده
Revealing the complex signal-processing mechanisms and interconnection patterns of the nervous system has long been an intriguing puzzle. As a contribution to its understanding the optimization of the impedance behavior of implantable electrode arrays with via holes is discussed here. Peripheral axons will regenerate through these holes allowing for simultaneous nerve stimulation and signal recording. This approach is part of the ESPRIT project INTER and may eventually lead to devices driving sensory motor prosthesis with closed loop control. In the first set of experiments, micromachined platinum electrode arrays were prepared, characterized and optimized for nerve signal recording. The results of these studies are based on impedance spectroscopy and microscopic techniques. Equivalent circuits were modeled describing formally the electrical response behavior with ohmic resistances between 500 omega and 10 k omega. To attain low impedances for all electrodes on the INTER device, platinum from H2PtCl6 was electrodeposited, and sputter technology as well as electrochemical deposition from H2IrCl6 solution were used to produce thin iridium films. For the former, a lift-off process was established at one of the institutes to generate electrode structures with a line width of 5 microns. As a result in all three cases the electrodes showed almost constant impedances over the entire frequency range (10 Hz-1 kHz), which is relevant for nerve signal recording. In the second set of experiments, electrodes were optimized to allow for nerve stimulation. For this purpose, the charge delivery capacity (CDC) had to be increased and the impedance had to be decreased. Iridium oxide is the material of choice, because its CDC is much higher than the CDC of platinum at 75 microC/cm2 (Ziaie et al., 1991, IEEE Sensors & Actuators Transducers, 6, 124-127). A significant increase of the electrochemically active surface of the electrode structures could be observed by measuring the surface roughness. In first experiments, an activated iridium oxide film was formed with cyclic voltammetry and was evaluated using scanning force microscopy and impedance spectroscopy. The evaluation of the cyclic voltammograms showed a CDC up to 400 mC/cm2 for sputter deposited and oxidatively treated iridium films. Further investigations are directed towards increasing the stability of the iridium oxide electrodes with regard to long-term implants. Parallel experiments aim at the controlled axon adhesion without changing the impedance behavior of the described electrodes.
منابع مشابه
Multi-electrode arrays technology for the non-invasive recording of neural signals: a review article
The recording of electrophysiological activities of brain neurons in the last half-century has been considered as one of the effective tools for the development of neuroscience. One of the techniques for recording the activity of nerve cells is the multi-electrode arrays (MEAs). Microelectrode arrays (MEAs) are usually employed to record electrical signals from electrogenic cells like neurons o...
متن کاملMicrofabrication and Characterisation of Microelectrode Arrays for in Vivo Nerve Signal Recording
The present work was performed in the framework of the ESPRIT-project "INTER" aimed at the development of an "intelligent" artificial interface between the living nerve system and electronic devices. The design, the fabrication, and the characterisation of regeneration-type microelectrode arrays for in vivo recording of nerve signals is described here. The impedance of the microelectrodes could...
متن کاملDesign, Fabrication, Simulation and Characterization of a Novel Dual-Sided Microelectrode Array for Deep Brain Recording and Stimulation
In this paper, a novel dual-sided microelectrode array is specially designed and fabricated for a rat Parkinson's disease (PD) model to study the mechanisms of deep brain stimulation (DBS). The fabricated microelectrode array can stimulate the subthalamic nucleus and simultaneously record electrophysiological information from multiple nuclei of the basal ganglia system. The fabricated microelec...
متن کاملAge-Dependent Regeneration by Using Electromyographical Study Foliowing Sciatic Nerve Injury in Rat
Purpose: There are extensive evidences that show axonal processes of the nervous system (peripheral and/or central) may be degenerated after nerve injuries. Axonal regeneration is relation to various factors. In this investigation we decided to evaluate the effects of nerve regeneration age-dependent on injured rat sciatic nerv. Materials and Methods: For this study, the right sciatic nerve of...
متن کاملIn Vivo Neural Recording and Electrochemical Performance of Microelectrode Arrays Modified by Rough-Surfaced AuPt Alloy Nanoparticles with Nanoporosity
In order to reduce the impedance and improve in vivo neural recording performance of our developed Michigan type silicon electrodes, rough-surfaced AuPt alloy nanoparticles with nanoporosity were deposited on gold microelectrode sites through electro-co-deposition of Au-Pt-Cu alloy nanoparticles, followed by chemical dealloying Cu. The AuPt alloy nanoparticles modified gold microelectrode sites...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Biosensors & bioelectronics
دوره 12 9-10 شماره
صفحات -
تاریخ انتشار 1997