Malposition of subclavian vein catheter inserted through indirect technique in a pediatric liver transplantation: a case report
نویسندگان
چکیده
INTRODUCTION Clinicians use either direct or indirect (Seldinger) techniques for internal juguler or subclavian vein catheterization. This report aims to point out that the success rate of the direct technique where the catheter is inserted directly through the cannula may be higher particularly in catheterization of pediatric cases. CASE PRESENTATION A 7.5-month-old female infant weighing 7200 gm was operated on for liver transplantation. The patient suffered jaundice at one month of age and was diagnosed with neonatal colestatic hepatitis. After routine monitoring, via indirect technique, central catheterization was attempted through internal jugular vein. However, the attempt failed. Therefore, again via indirect technique, catheterization was achieved through the right subclavian vein and fixed at 8 cm. After the operation started, fluid replacement and central venous pressure monitoring were performed with this catheter. Immediately after the operation, a control postero-anterior chest radiograph of the patient was obtained. This graph revealed that the tip of the catheter was fixed in the right internal jugular vein. Since the vital symptoms of the patient were not stable, the catheter was not removed and fluid replacement was performed via this technique. The catheter was removed on the postoperative 2(nd) day. CONCLUSION The J wire advanced via the indirect technique advances anatomically following the upper wall of subclavian vein. Because of the smaller vessel dimensions and sharper, more angulated routes the subclavian and internal jugular veins make in infants, the rigid J wire may advance in the cephalic direction. However, in the technique where the catheter (Cavafix ((R)) catheter) is inserted directly through the cannula, this probability is less since J wire is not used and the catheter employed is flexible. We concluded that especially in pediatric cases, employment of the technique where the catheter is inserted directly through the cannula would be more convenient in order to decrease the catheter malpositioning probability.
منابع مشابه
Correction of malposition of central venous catheter with 9-Fr introducer sheath assisted by mobile type diagnostic X-ray apparatus: a case report
Central venous catheters provide long-term available vascular access. They are useful for central venous pressure monitoring, rapid fluid management, massive transfusion and direct cardiovascular medication, especially in operation. Central venous catheterization is usually performed by the landmark bedside technique without imaging guidance. The complications of central venous catheterization ...
متن کاملA catheter malpositioned patient with pain and paresthesia
We report a 54-year-old woman with the history of end-stage renal disease (ESRD) who was admitted to our hospital because of volume overload. Due to long-term use of peripheral veins and arteriovenous fistula (AVF) failure, central venous catheterization was the only choice for hemodialysis. She developed right upper extremiti’s pain and paresis during hemodialysis. A posteroanterior chest x-ra...
متن کاملSubclavian vein dialysis access catheter-complications are low.
Internal jugular vein has been recommended as the vascular access for haemodialysis because it is associated with less thrombotic/stenotic complication. Despite this recommendation, subclavian vein access is still being frequently used. This paper aims at reviewing the rate of complications associated with temporary double lumen subclavian vein dialysis access catheter in a personal series. It ...
متن کاملCatheter malposition following supraclavicular approach for subclavian vein catheterisation--case reports.
The supraclavicular approach of subclavian vein catheterization is associated with the lowest incidence of malposition. We report two cases of unusual malpositions seen during central venous cathelerization of subclavian vein via supraclavicular approach. Literature search did not reveal such malpositions. The possible cause for the malposition and method to prevent it is discussed.
متن کاملA Rare Central Venous Catheter Malposition: A Case Report
INTRODUCTION Central venous catheter placement is a routine procedure for the management of critically ill patients; however, it is important to ensure its proper placement. A central venous catheter malposition may cause various complications, some of which can be fatal. CASE PRESENTATION We report an unexpected malposition of a catheter in the left internal jugular vein, where it entered in...
متن کامل