Energy Expenditure Evaluation in Humans and Non-Human Primates by SenseWear Armband. Validation of Energy Expenditure Evaluation by SenseWear Armband by Direct Comparison with Indirect Calorimetry
نویسندگان
چکیده
INTRODUCTION The purpose of this study was to compare and validate the use of SenseWear Armband (SWA) placed on the arm (SWA ARM) and on the back (SWA BACK) in healthy humans during resting and a cycle-ergometer exercise and to evaluate the SWA to estimate Resting Energy Expenditure (REE) and Total Energy Expenditure (TEE) in healthy baboons. METHODS We studied 26 (15F/11M) human subjects wearing SWA in two different anatomical sites (arm and back) during resting and a cycle-ergometer test and directly compared these results with indirect calorimetry evaluation (IC), performed at the same time. We then inserted the SWA in a metabolic jacket for baboons and evaluated the TEE and REE in free living condition for 6 days in 21 (8F/13M) non-human primates. RESULTS In humans we found a good correlation between SWA place on the ARM and on the BACK with IC during the resting experiment (1.1±0.3 SWAs, 1±0.2 IC kcal/min) and a slight underestimation in the SWAs data compared with IC during the cycle-ergometer exercise (5±1.9 SWA ARM, 4.5±1.5 SWA BACK and 5.4±2.1 IC kcal/min). In the non-human primate (baboons) experiment SWA estimated a TEE of 0.54±0.009 kcal/min during free living and a REE of 0.82±0.06 kcal/min. CONCLUSION SWA, an extremely simple and inexpensive apparatus, provides quite accurate measurements of energy expenditure in humans and in baboons. Energy expenditure data obtained with SWA are highly correlated with the data obtained with "gold standard", IC, in humans.
منابع مشابه
SenseWear Armband and Stroke: Validity of Energy Expenditure and Step Count Measurement during Walking
The purpose of this study was to test the validity of the SenseWear Pro Armband (SWA) for the measurement of energy expenditure (EE) and step count against a criterion in persons with stroke. Twelve participants with chronic stroke (mean age 64.2 ± 10.4 years; mean gait speed 0.67 ± 0.25 m/sec) completed two trials of a six-minute walk test, while wearing a SenseWear Armband (SWA) on each arm a...
متن کاملAbstract -- The ability to accurately and reliably monitor physical activity and energy expenditure has emerged as a critical component to weight management and the prevention of lifestyle related health
The ability to accurately and reliably monitor physical activity and energy expenditure has emerged as a critical component to weight management and the prevention of lifestyle related health problems. Current methods and tools used by researchers, clinical practitioners, and individuals to assess physical activity and energy expenditure were reviewed and found to have practicality and accuracy...
متن کاملThe Development of the SenseWear® armband, a Revolutionary Energy Assessment Device to Assess Physical Activity and Lifestyle
Consumers, clinicians, and researchers lack an easy-to-use, reliable and cost effi cient way to accurately assess metabolic physical activity and energy expenditure, critical components of a variety of behavioral modifi cation programs, including diseaseand weight-management. BodyMedia has addressed this need by developing the SenseWear Pro2 Armband which utilizes a heat fl ux sensor, galvanic ...
متن کاملEnergy expenditure and habitual physical activities in adolescent sprint athletes.
This study aimed to assess total energy expenditure (TEE) and specific habitual physical activities in adolescent sprint athletes. Two methods used to estimate TEE, an activity diary (AD) and SenseWear armband (SWA), were compared. Sixteen athletes (6 girls, 10 boys, mean age 16.5 ± 1.6 yr) simultaneously wore a SWA and completed an AD and food diary during one week. Basal energy expenditure as...
متن کاملAccuracy of a portable multisensor body monitor for predicting resting energy expenditure in older people: a comparison with indirect calorimetry.
BACKGROUND Accurate and comfortable methods are needed to determine resting energy expenditure (REE) in older people who are characterized by a lowered metabolic rate. The portable SenseWear® armband (SWA) body monitor, worn on the right upper arm, can easily be used by this age group in an ambulatory manner. OBJECTIVE The purpose of this study was to evaluate the reliability and accuracy of ...
متن کامل