Quantification of the Relaxation Times of Combined CT and MR Contrast Agents for Optimal Imaging at MR Arthrography
نویسندگان
چکیده
Introduction Using both iodinated X-ray contrast and gadolinium (Gd) based MR contrast agents is helpful when performing MR arthrography. Joint visualization is enhanced if fluoroscopy is used for needle placement and a CT exam can be performed without an additional needle stick if the MR arthrogram is unsuccessful. However, the presence of iodinated contrast alters the relaxivity of gadolinium based MR contrast agents [1]. In order to optimize the image contrast for MR arthrography, the effect of iodinated contrast agents on the relaxation property of Gd contrast must be understood [2]. The purpose of this study is to measure the T1 and T2 relaxation times of solutions with different combinations of Gd and iodine concentrations and at different magnetic field strengths in order to model their dependences. Such information can then be used to predict the optimal gadolinium and iodine concentrations for direct arthrography for a given MRI protocol. Methods Three different type of Gd contrast agents, MultiHance (gadobenate dimeglumine, Bracco, Princeton, NJ), ProHance (gadoteridol, Bracco, Princeton, NJ) and Magnevist (Gd-DTPA, Berlex, Wayne, MI) were mixed with a single iodinated contrast agent, Isovue-370 (iopamidol 76%; Bracco, Princeton, NJ) and diluted with clinical-grade saline (0.9% sodium chloride solution) to produce three sets of solutions with different Gd concentrations of 2, 1, 0.5, 0.25, 0.125, 0 mmol/L and iodine concentrations of 370, 185, 92.5, 46.25, 0 mg/mL. Vials filled with these Gd and iodine mixtures were embedded in Play-Doh prior to MRI scans. Measurement of relaxation times was made using GE 0.7T OpenSpeed, Siemens 1.5T Symphony and Siemens 3.0T TIM Trio scanners. An IR-FSE sequence with ETL of 3, TI times of 50, 100, 200, 400, 800, 1600, 4000 ms and TR of 10 sec were used to acquire images for T1 mapping. A SE sequence with minimum TE times possible for each scanner (10-16 ms) as well as 20, 40, 80, 160 and 320 ms and a TR time of 3.5 sec was used to acquire images for T2 mapping. A non-linear least squares fitting algorithm was used to calculate the T1 and T2 values pixel by pixel [3], and a user defined ROI was placed inside each sample region in the T1 and T2 maps to estimate the T1 and T2 relaxation times for each combination of Gd and iodine concentration. Finally, for each field strength and type of Gd contrast agent, the T1 and T2 relaxation times were fitted with two-variable linear models: 1/T1 = R01 + R1Gd[XGd] + R1I[XI] + R1Gd_I[XGd][XI] and 1/T2 = R02 + R2Gd[XGd] + R2I[XI] + R2Gd_I[XGd][XI], where [XGd] and [XI] are Gd and iodine concentrations, to determine the coefficients: R10, R1Gd, R1I, R1Gd_I, R20, R2Gd, R2I and R2Gd_I. Results Figure 1 a) Representative image of MultiHance and Isovue mixtures acquired with TI=200ms at 1.5T. b) T1 map of MultiHance and Isovue mixtures at 1.5T. c) Two-variable regression of T1 values of MultiHance and Isovue mixtures with different concentrations.
منابع مشابه
Recent Advances in PET-MR Hybrid contrast agent
Introduction: All of the Imaging modalities have advantages and disadvantages alone. So if we want to have the best and perfect image, combining these modalities produces something we desired. PET-MR images consist of morphologic and metabolic data. MRI and PET provide high spatial and contrast resolution and high sensitivity and molecular information respectively. Hybrid PET-...
متن کاملSynthesis and Application of New Gadolinium-Porphyrins as Potential MR Imaging Contrast Agents for Cancer Detection in Nude Mice
Two new potential magnetic resonance imaging contrast agents, Gd-hematoporphyrin (Gd-H) and Gd-tetra-carboranylmethoxyphenyl-porphyrin (Gd TCP), were synthesized and applied to nude mice with human melanoma (MM 138) xenografts. These agents showed a high relaxivity because of their greater potential to coordinate water molecules. The reduction of T1 relaxation times of 16 and 21% was observed i...
متن کاملComparison of state-of-the-art atlas-based bone segmentation approaches from brain MR images for MR-only radiation planning and PET/MR attenuation correction
Introduction: Magnetic Resonance (MR) imaging has emerged as a valuable tool in radiation treatment (RT) planning as well as Positron Emission Tomography (PET) imaging owing to its superior soft-tissue contrast. Due to the fact that there is no direct transformation from voxel intensity in MR images into electron density, itchr('39')s crucial to generate a pseudo-CT (Computed Tomography) image ...
متن کاملOptimization of the Contrast Mixture Ratio for Simultaneous Direct MR and CT Arthrography: an in Vitro Study
OBJECTIVE This study was designed to determine the optimal mixture ratio of gadolinium and iodinated contrast agent for simultaneous direct MR arthrography and CT arthrography. MATERIALS AND METHODS An in vitro study was performed utilizing mixtures of gadolinium at six different concentrations (0.625, 1.25, 2.5, 5.0, 10 and 20 mmol/L) and iodinated contrast agent at seven different concentra...
متن کاملMultifunctional GQDs-Coated Fe/Bi Nanohybrids for CT/MR Dual Imaging and in vitro Photothermal Therapy
Introduction: The multipurpose nanocomposites have gained growing biomedical attention as promising nanotheranostics to improve The effectiveness of cancer treatment, which concurrently combine advantages of the therapeutic and diagnostic techniques into one nanosystem. The “all-in on” probes not only help to ablate cancerous tumors, but also allow to optimize and monitoring of...
متن کامل