Phacoemulsification Induced Transient Swelling of Corneal Descemet’s Endothelium Complex Imaged with Ultra-High Resolution Optical Coherence Tomography

نویسندگان

  • Aizhu Tao
  • Zhao Chen
  • Yilei Shao
  • Jianhua Wang
  • Yune Zhao
  • Ping Lu
  • Fan Lu
چکیده

PURPOSE Thickness changes of corneal sub-layers after phacoemulsification were investigated by spectral domain ultra-high resolution optical coherence tomography (UHR-OCT). METHODS The corneas (n = 26) of 26 age-related cataract surgery patients were studied. UHR-OCT was used to evaluate the thickness of Descemet's Endothelium Complex (DEC), stroma, Bowman's layer, epithelium, and full cornea at the center (CCT) before, one day after, and one week after surgery. Non-contact specular microscopy measured CCT, endothelial cell density, and morphology. RESULTS The DEC, stroma, Bowman's layer, and epithelium were visualized by UHR-OCT. Before surgery, the DEC in all cases appeared as a translucent space between two smooth opaque lines. One day after surgery, the posterior corneal surfaces in half of the eyes were wavy and irregular. Compared to the baseline, one day after surgery the thickness increases of the DEC, stroma, and CCT were 4.3 ± 2.6 µm, 25.5 ± 24.9 µm, and 32.1 ± 26.6 µm, respectively (P < 0.001). The morphology of the DEC and the CCT recovered to baseline one week after surgery (P > 0.05), but endothelial cell density was 8.7% less than at baseline. There were no significant changes in Bowman's layer and epithelium after the operation. The pre-operative DEC thickness was positively correlated with the decreased endothelial cell density at 1 day after surgery (r = 0.55, P = 0.003). CONCLUSIONS The DEC showed edematous thickening and different degrees of morphological changes after phacoemulsification. The DEC deformation and corneal edema recovered by one week after surgery, which indicated recovery of endothelial function. UHR-OCT is a useful tool to evaluate function of the DEC after phacoemulsification. Pre-operative DEC thickness may indicate the integrity of the endothelium and could be used for predicting endothelial cell loss after phacoemulsification.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of hypoxic swelling of human cornea with high speed, ultrahigh resolution optical coherence tomography

Hypoxia induced corneal swelling was observed and evaluated in healthy human volunteers by use of high speed, ultrahigh resolution optical coherence tomography (UHROCT). Two dimensional corneal images were acquired at a speed of 47,000 A-scans/s with 3μm x 10μm (axial x lateral) resolution in corneal tissue. The UHROCT tomograms showed clear visualization of all corneal layers, including the Bo...

متن کامل

In vivo corneal high-speed, ultra high-resolution optical coherence tomography.

OBJECTIVE To introduce new corneal high-speed, ultra-high-resolution optical coherence tomography (hsUHR-OCT) technology that improves the evaluation of complicated and uncomplicated cataract, corneal, and refractive surgical procedures. DESIGN This case series included a control subject and 9 eyes of 8 patients who had undergone phacoemulsification, Descemet membrane stripping endokeratoplas...

متن کامل

Optical Coherence Tomography Findings in Anterior Chamber Ointment Globule after Phacoemulsification.

We present 2 cases of anterior chamber ointment with evidence of progressive endothelial cell loss. In both cases, an anterior segment optical coherence tomography (OCT) was similar to an OCT of a tobramycin-dexamethasone ointment placed on a pen tip. An anterior segment OCT also demonstrated the direct contact of the globule with the corneal endothelium. A gas chromatography/mass spectrometry ...

متن کامل

Anterior Vitreous Incarceration after Phacoemulsification Cataract Extraction Imaged with Spectral-Domain Optical Coherence Tomography

Background: Anterior vitreous incarceration is a condition in which vitreous prolapses into the anterior chamber and passes through a microscopic wound at an incisional site. The condition can be identified as a vitreous strand leading to the wound site during slit lamp examination. If the vitreous strand penetrates through all the corneal layers on to the extraocular surface it becomes vitreou...

متن کامل

Vertical and Horizontal Corneal Epithelial Thickness Profile Using Ultra-High Resolution and Long Scan Depth Optical Coherence Tomography

PURPOSE To determine the vertical and horizontal thickness profiles of the corneal epithelium in vivo using ultra-long scan depth and ultra-high resolution spectral domain optical coherence tomography (SD-OCT). METHODS A SD-OCT was developed with an axial resolution of ∼ 3.3 µm in tissue and an extended scan depth. Forty-two eyes of 21 subjects were imaged twice. The entire horizontal and ver...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2013