AIAA 96-2236 Comparison of theoretical laser-induced fluorescence images with measurements performed in a hypersonic shock tunnel
نویسنده
چکیده
Planar laser-induced fluorescence (PLIF) images of hypersonic flow over a wedge are compared with a theoretical PLIF model. The synthetic images, which include the effects of collisional quenching, are based on a perfect-gas treatment of the fluid mechanics, assuming frozen chemistry. We find very good agreement between the model and the experimental measurements.
منابع مشابه
Numerical simulation of laser-induced fluorescence imaging in shock-layer flows
Planar laser-induced fluorescence (PLIF) images of nitric oxide (NO) in hypersonic flow over a wedge and a hemisphere are compared with a theoretical PLIF model. The theoretical PLIF images are based on computational fluid dynamics (CFD) models including a perfect-gas model and a nonequilibrium chemistry model. Two dimensional maps of the flow parameters generated by the CFD are used to predict...
متن کاملInvestigation of Shock Wave Interaction Using Laser-induced Iodine Fluorescence
Detailed measurements of flow behavior have been taken in a rarefied ‘slip-flow’ regime hypersonic flow (Mach 12) over a sharp edged flat plate with a circular-cylindrical appendage designed to produced shock wave interactions. The flat plate is presented parallel to the wind tunnel freestream to generate a weak shock which impinges on the nearly-normal cylinder bow shock wave. Tests were condu...
متن کاملAIAA 2002-2917 Nonintrusive Temperature and Velocity Measurements in a Hypersonic Nozzle Flow
Distributions of nitric oxide vibrational temperature, rotational temperature and velocity have been measured in the hypersonic freestream at the exit of a conical nozzle , using planar laser-induced fluorescence. Particular attention has been devoted to reducing the major sources of systematic error that can affect fluorescence temperature measurements, including beam attenuation, transition s...
متن کاملAIAA 99-0772 Measurement of NO Density in a Free- Piston Shock Tunnel using PLIF
We investigate the feasibility of using a combined absorption – planar laser-induced fluorescence (PLIF) method for measuring nitric oxide (NO) number density in the freestream of a free-piston shock tunnel. The absorption coefficient is determined from the exponential decay in PLIF intensity through a uniform region of flow. The NO density is determined from the measured absorption coefficient...
متن کاملTwo-dimensional velocity-field measurement in a hypersonic gas flow over a cone using planar laser-induced fluorescence
Planar laser-induced fluorescence (PLIF) of nitric oxide is used to measure a component of the velocity field for the Mach 7 flow around a cone. Velocities are measured in the freestream, shock layer, and the separated region behind the cone. The measurements are compared with computational fluid dynamics (CFD) codes. The comparison indicates that the CFD correctly predicts the flow over the fo...
متن کامل