Comparison of the Results of Studies of Air Pollution Fungi Using the SAS Super 100, MAS 100, and Air IDEAL

نویسندگان

  • Cecylia Łukaszuk
  • Elżbieta Krajewska-Kułak
  • Andrzej Guzowski
  • Wojciech Kułak
  • Bogumiła Kraszyńska
چکیده

Although several air sampling devices for identifying and enumerating airborne microorganisms are commercially available, each poses some limitations. The aim of this study was to evaluate air pollution fungi using three such samplers: SAS Super 100, Microbiological Air Sampler (MAS) 100, and Air IDEAL. Mycological air was taken from the cellars of a 17th-century church in Siemiatycze, Poland, and the nearby outdoor environment. With samplers placed 1.5 m above the floor, microbial flora in air samples collected inside and outside the cellar were detected. The number of colony-forming units (CFU) of fungi obtained with the three samplers from the cellars and outdoor environment differed; the most CFU were obtained with the Air IDEAL and the least with the SAS Super 100. Significant differences emerged in CFUs collected from air samples with the MAS 100 and SAS Super 100, on the one hand, and the SAS Super 100 and Air IDEAL, on the other. Otherwise, results among the samplers were different. More Cladosporium species were collected with the MAS 100 sampler, whereas more Fusarium and Aspergillus species were collected with the Air IDEAL sampler. Significant differences among CFU/m³ values among the tested sites depended on the sampler used.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Indoor air studies of fungi contamination at the Neonatal Department and Intensive Care Unit an Palliative Care in Kavala Hospital in Greece.

PURPOSE The assessment of the indoor air and walls contamination of fungi at the Kavala Hospital in Greece was made. MATERIAL AND METHODS The study was carried out at the Neonatal Department and Intensive Care Unit and Palliative Care in Kavala Hospital (Greece). Materials for the tests were: the air samples (in front of the building and the selected rooms) and swabs from the walls. The air p...

متن کامل

Indoor air studies of fungi contamination at the Department of Pulmonology and Internal Medicine in Kavala Hospital in Greece.

PURPOSE The aim of the study was to assess the presence of airborne fungi and the fungal flora of the walls in the Departments of Pulmonary and Internal Medicine in Kavala Hospital (Greece). MATERIAL AND METHODS The study was carried out at the Department of Pulmonology and Internal medicine in Kavala Hospital. Materials for the tests were: the air samples (in front of the building and the se...

متن کامل

Analysis of the incidence of fungal pathogens in air of the Department of Dermatology, Venereology and Allergology of Medical University in Wrocław.

PURPOSE Analysis of incidence of fungal pathogens in air of Department of Dermatology, Venereology and Allergology of Medical University in Wrocław. MATERIAL AND METHODS Materials for the tests were: the air samples in front of the building, corridors, library, lecture hall, and mycological laboratory. The air pollution was determined using SAS SUPER 100. Humidity and temperature were evaluat...

متن کامل

Review of studies on air quality status and its health effects in Iran

Background and Objective: Air pollution is a leading environmental risk factor on health and it is the major cause of death and disease at global level. Air pollution has been shown to have a significant share in the non-communicable diseases (NCDs) burden. After smoking, it is the second cause of deaths due to NCDs, associated with an increased risk of developing acute and chronic diseases and...

متن کامل

Accuracy comparison of Elamn and Jordan artificial neural networks for air particular matter concentration (PM 10) prediction using MODIS satellite images, a case study of Ahvaz.

Due to the complexity of air pollution action, artificial intelligence models specifically, neural networks are utilized to simulate air pollution. So far, numerous artificial neural network models have been used to estimate the concentration of atmospheric PMs. These models have had different accuracies that scholars are constantly exceed their efficiency using numerous parameters. The current...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 14  شماره 

صفحات  -

تاریخ انتشار 2017