The diagnostic performance evaluation of the SD BIOLINE HIV/syphilis Duo rapid test in southern Ethiopia: a cross-sectional study

نویسندگان

  • Techalew Shimelis
  • Endale Tadesse
چکیده

OBJECTIVE To determine the diagnostic performance of the SD BIOLINE HIV/syphilis Duo rapid test. DESIGN A hospital-based cross-sectional study. SETTING This evaluation was conducted at one of the largest hospitals in southern Ethiopia. PARTICIPANTS Serum samples obtained from clients attending the antiretroviral therapy and voluntary counselling and testing centres were used. Sera were originally collected for the purpose of investigating syphilis epidemiology. The performance of the test to detect HIV was evaluated using 400 sera (200 HIV positives and 200 HIV negatives). Also, its performance to detect syphilis was evaluated using 85 syphilis positive and 100 syphilis negative serum samples. Individuals <15 years of age or syphilis treated or those with ≤50 cells/µL CD4 cell count were originally excluded. OUTCOME MEASURES HIV screening was carried out according to the national rapid diagnostic testing (RDT) algorithm: Shenghai Kehua Bioengineering (KHB) test kit as a screening test, followed by the HIV1/2 STAT-PAK assay if positive. Where the result of the STAT-PAK is discordant with KHB, Unigold HIV is used as a tiebreaker to determine the result. We also used ELISA to resolve discordant HIV results. Syphilis serostatus was determined using the Treponema pallidum haemagglutination assay (TPHA). RESULTS The respective sensitivity, specificity, positive predictive value and negative predictive value of the SD BIOLINE HIV/syphilis Duo test were 100, 99.5, 99.5 and 100% for HIV and 97.6, 96, 95.4 and 98% for syphilis testing, respectively. In reference to TPHA, the test kit reported 4 false positives and 2 false negative results for syphilis. The κ values were 0.99 for HIV testing and 0.94 for syphilis testing. CONCLUSIONS The excellent performance of the SD BIOLINE HIV/syphilis Duo test to detect HIV as well as syphilis facilitates the integration of syphilis testing and treatment to the already established HIV prevention programme, ultimately contributing to the dual HIV and syphilis elimination goal.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of SD Bioline HIV/syphilis Duo rapid test kits in Nepal

BACKGROUND Accurate and prompt diagnosis of HIV and syphilis simultaneously has reinforcing effect on their control program because of their prevalent co-infection. Availability of a simple user-friendly two-pronged and affordable detection tools brings down the cost of health care. They are important in the antenatal clinics, with added opportunity for intervention and prevention of mother to ...

متن کامل

Multisite Laboratory Evaluation of a Dual Human Immunodeficiency Virus (HIV)/Syphilis Point-of-Care Rapid Test for Simultaneous Detection of HIV and Syphilis Infection

BACKGROUND Recently, test developers have created rapid point-of-care tests that can simultaneously detect multiple infections within the same specimen using a single device. The SD BIOLINE Duo HIV/Syphilis rapid point-of-care test uses a solid-phase immunochromatographic assay to detect immunoglobulin (Ig)G, IgM, and IgA antibodies to human immunodeficiency virus (HIV)-specific antigens (HIV-1...

متن کامل

An evaluation of the SD Bioline HIV/syphilis duo test

Many health agencies now recommend routine HIV and syphilis testing for pregnant women and most-at-risk populations such as men who have sex with men. With the increased availability of highly sensitive, low cost rapid point-of-care tests, the ability to meet those recommendations has increased, granting wider access to quick and accurate diagnoses. Using blood specimens collected from a Baltim...

متن کامل

Diagnostic Performance Evaluation of the Sd Bioline Malaria Antigen Ag Pf/pan Test (05fk60) in a Malaria Endemic Area of Southern Ethiopia

Rapid diagnostic tests (RDTs) capable of detecting and differentiating Plasmodium species are needed in areas in which microscopy is unsuitable. This study was conducted to assess the diagnostic performance of the rapid test kit - SD BIOLINE Malaria Ag Pf/Pan(r) (05FK60) in an endemic area. Microscopy of Giemsa-stained blood films were performed to detect and estimate the Plasmodium density in ...

متن کامل

Dual rapid lateral flow immunoassay fingerstick wholeblood testing for syphilis and HIV infections is acceptable and accurate, Port-au-Prince, Haiti

BACKGROUND Dual rapid tests for HIV and syphilis infections allow for detection of HIV infection and syphilis at the point-of-care. Those tests have been evaluated in laboratory settings and show excellent performance but have not been evaluated in the field. We evaluated the field performance of the SD BIOLINE HIV/Syphilis Duo test in Port-au-Prince, Haiti using whole blood fingerprick specime...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2015