A densitometer for quantitative autoradiography.

نویسندگان

  • G W Dauth
  • K A Frey
  • S Gilman
چکیده

A low cost spot densitometer system is described. This system is useful for quantitative autoradiography of local cerebral glucose utilization, blood flow, receptor binding and other applications requiring densitometry on films. The densitometer can be used alone or interfaced to a microcomputer. The densitometer consists of a photographic enlarger, a digital multimeter, and the densitometer electronics. We have described how to construct, test and use the densitometer and how to interface the densitometer to a microcomputer. The advantages of this system are: (1) the ability to enlarge the image for accurate measurements from 'small' areas; (2) a completely unobscured image during measurement; (3) low cost and (4) ease of use.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

High-resolution densitometry: analysis of stained albumin bands as a model for electrophoresis of serum proteins.

In discussing the principles of quantitative analysis in thin-layer media, we show that requirements for quantitative analysis are not satisfied when stained protein electrophoretic bands are scanned with a conventional rectangular-slit densitometer. We investigated a high-resolution densitometer based on a linear photodiode array as an alternative analytical tool, using stained electrophoretic...

متن کامل

Concordance of macular pigment measurements obtained using customized heterochromatic flicker photometry, dual-wavelength autofluorescence, and single-wavelength reflectance.

This study compares in vivo measurements of macular pigment (MP) obtained using customized heterochromatic flicker photometry (cHFP; Macular Metrics Densitometer(™)), dual-wavelength fundus autofluorescence (Heidelberg Spectralis(®) HRA + OCT MultiColor) and single-wavelength fundus reflectance (Zeiss Visucam(®) 200). MP was measured in one eye of 62 subjects on each device. Data from 49 subjec...

متن کامل

Relation of prenatal and postnatal status to calcaneus quantitative ultrasound in adolescents.

This study aimed to elucidate the relationship of prenatal and/or postnatal factors, including acquired factors, with the calcaneus stiffness index as measured by quantitative ultrasound (QUS-SI) in adolescents. We recruited 1,143 adolescents with a mean age of 14.8 ± 1.8 years (501 boys and 642 girls). The subjects' calcaneus QUS-SI was measured using an ultrasound bone densitometer. We also m...

متن کامل

Quantitative autoradiography using a personal computer.

A video digitizing system based on an Apple II personal computer has been developed for use in quantitative autoradiography. The selection process of an acceptable video camera, an illumination system, and the functions provided in the software are discussed. This system is in routine use and has been duplicated by several other laboratories.

متن کامل

Comparison of DXA , SXA and QUS

Methods: We carried out measurements of bone mineral density (BMD) of lumbar spine and femoral neck using DXA, QUS of heel using ultrasound densitometer, and BMD of forearm using SXA. We performed all the measurements at the Nuclear Medicine Division of King Khalid University Hospital, Riyadh, Kingdom of Saudi Arabia between 2002 and 2004. We obtained the measurements of 437 female adult patien...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of neuroscience methods

دوره 9 3  شماره 

صفحات  -

تاریخ انتشار 1983