Tip Apex Distance: a useful method to assess extra-capsular neck of femur fixation?
ثبت نشده
چکیده
The Tip Apex Distance (TAD) is a simple measurement that predicts screw cut-out in the femoral head from trochanteric fractures treated with a fixed angle sliding hip screw device [1]. It uses a numerical value to show placement of the screw in the head: higher values indicating higher likelihood of fixation failure by extrusion of the screw. Currently the cost of hip fracture care in the UK is great, at an estimated £1.4 billion per annum [2]. In order to examine the care delivered to these 70,000 patients affected by a neck of femur fracture, The National Hip Fracture Database (NHFD) collects information about case-mix, care and patient outcomes. However, actual data pertaining to the adequacy of fixation for fracture treatment is not routinely audited. Analysis of NHFD data according to fracture subtypes has shown that for the UK population: 41% were displaced intracapsular, 13% undisplaced intracapsular, 35% intertrochanteric and 6% subtrochanteric fractures [2]. Intertrochanteric fractures therefore comprise a significant proportion of the fractures sustained in the population. Nationally, the majority (81%) were treated by a sliding hip screw device [2].
منابع مشابه
Changes in Tip-Apex Distance by Position and Film Distance Measured by Picture Archiving and Communication System (PACS)
PURPOSE The tip-apex distance (TAD) is used to predict the clinical outcome of intertrochanteric fracture fixation. We aimed to measure the changes in TAD by position and film distance using Picture Archiving and Communication System (PACS). MATERIALS AND METHODS We used a femur replica with a 10° femoral neck anteversion and a 130° neck shaft angle. Proximal femoral nail antirotation nail an...
متن کاملReview of methods to quantify lag screw placement in hip fracture fixation.
This review considers methods used to quantify lag screw placement within the femoral head following proximal femoral fracture. Implants used for fixation of femoral neck fractures can lead to unwanted outcomes in some patients. Cutting out of the screw within the femoral head has been shown to be the commonest cause of failure and is related to lag screw placement within the femur. Until now, ...
متن کاملNumerical Optimization of the Position in Femoral Head of Proximal Locking Screws of Proximal Femoral Nail System; Biomechanical Study
BACKGROUND Proximal femoral fracture rates are increasing due to osteoporosis and traffic accidents. Proximal femoral nails are routinely used in the treatment of these fractures in the proximal femur. AIMS To compare various combinations and to determine the ideal proximal lag screw position in pertrochanteric fractures (Arbeitsgemeinschaft für Osteosynthesefragen classification 31-A1) of th...
متن کاملMultiple radiographic projections in detecting intra-articular screw penetration during fixation of femoral neck fractures.
The authors performed a cadaveric study to evaluate the efficacy of multiple fluoroscopic projections in detecting intra-articular penetration of the screws during femoral neck fracture fixation and also to determine the most suitable radiographic projection. Models of intra-articular penetration in 8 normal proximal femur specimens were created by placing the pins in different quadrants of the...
متن کاملSubcapital femoral neck fracture after fixation of an intertrochanteric fracture with a proximal femoral nail: a report of two cases.
Subcapital femoral neck fractures are a rare complication after fixation of an intertrochanteric fracture with a proximal femoral nail. We report 2 such cases where the patients had severe osteoporosis, based on Singh's index and pathological findings. In one case there was a technical error leading to a tip-apex distance of more than 20 mm, but osteoporosis appeared to be a more significant ca...